Common Problems and Questions About 3151 Terminals
 
Contents
About this document
Common problems
Common questions
Sample settings for 3151
 
This document applies to AIX Versions 3.2.3 through 3.2.5. 
 
Function keys not working
 
Function keys may not work for the following reasons: 
 
- AIX requires "Turnaround Character = CR" in Communication Setup menu; the 
default is ETX. 
- Perhaps you are using 3151 Model 510/610 and a host application that 
requires redefinable function keys.  The Model 510/610 DOES NOT support 
redefinable function keys.  Recommend using models 310/410. 
- An application (example UNIPLEX) may redefine function keys on models 
310/410 and not reset them back to default values when exiting.  The host needs 
to transmit 3151 "Set All Default Function Keys" command (ESC SP t).  Operator 
can reset function keys in DEF F setup by pressing the Clear key. 
Insert key not working
 
If the insert key does not work, change the INSERT CHARACTER setup option 
from MODE to SPACE. 
Double characters displayed
 
If double characters are displayed, change the OPERATING MODE from CHAR to 
ECHO. 
Double prompt when enter/return key is pressed
 
The New Line option must be set to CR, not CR/LF. If it is not, it may cause 
a double prompt when the Return/Enter key is pressed.  The New Line option can 
be changed either from the setup menus or from the host. 
Setup: 
 
- Keyboard setup menu.  (Models 110, 310, 410 only) 
- Select "Default" in Function setup menu. 
Host:  Set Control 2 Command:  ESC ! 9 ( J 
3151 locks up
 
If the display locks up: 
 
- Turn on "Status Line" either from keyboard or from setup.  This provides 
additional information.  The following items may be displayed on status line: 
 
-  
HOST BUSY 
- Host told 3151 not to send data to host.  Problem must be corrected at 
host. 
-  
KEYS LOCKED 
- Host sent "Keyboard Lock" command.  Host must send "Keyboard Unlock" 
command.  Problem must be corrected at host. 
-  
HOLD SCREEN 
- Operator pressed "Hold" or "Pause" key; must press "Hold" or "Pause" key 
again. 
 
- It may be that the operator accidentally pressed Ctrl-S (XOFF); Press 
Ctrl-Q (XON) to fix the problem. 
3151 does not communicate with host
 
If the 3151 does not communicate with the host: 
 
- Turn on "Status Line".  If "COMM NOT READY 2" is displayed, change "Line 
Control" = IPRTS. 
- Host cable may be attached to the auxiliary port rather than the main port. 
The main port is on the right-hand connector ("right hand" as you are looking 
from the back). 
- The Transmit Data, Receive Data pins may not match the host communications 
port.  Check pin configuration on the host system. 
- The host system may not have the communications port enabled. 
- If the second session is not working with the Connectivity Cartridge in 
Dual Session by Dual Port, the directions of pins 2 (TD) and 3 (RD) are 
reversed.  Switch pins 2 and 3 on the communications cable attached to the 
Auxiliary port. 
Missing or lost characters
 
Missing or lost characters may be caused by a pacing problem.  Reduce line 
speed to 2400 or 4800 to confirm that the problem is pacing.  Activate pacing 
at the 3151 and the host. 
Lost setup values
 
If setup values are lost: 
 
- The host could be changing setup values by various 3151 commands: Set 
Control, Create Viewport. 
- Perhaps the user changed the setup options in the setup menu, but never 
performed the "Save" operation (move cursor to "Save" and press space bar). 
Cannot get into setup
 
If you cannot get into setup: 
 
- The problem may be a mismatch of keyboards with the video element. 
 
- If you have a 110 video element with a 310/410/510/610 keyboard, press 
Ctrl-F4 to enter the setup. 
- if you have a 310/410/510/610 video element with a 110 keyboard, it is 
impossible to enter the setup. 
 
- It may be that DEC VT200/VT100/VT52 emulation is selected and the keyboard 
does not have the DEC Keycap kit.  Press the F3 key, the location of the setup 
key when in DEC emulation. 
Cannot print, not printing correctly
 
If you cannot print or if printing is incorrect: 
 
- Make sure the printer is a serial printer, not a parallel printer. 
- Make sure the correct cable is being used with printer.  Note the 
directions of the Receive and Transmit data pins. 
3151 displays backward question marks
 
Backward question marks are caused by a frame error; the parity, word 
length, stop bits, and line speed must match the host system. 
The (*,/,-,Alt,Ctrl,Page Up,Page Down) keys are not 
working
 
With a model 510/610 in ASCII Mode, the keyboard becomes a 310/410 ASCII 
layout.  This creates the symptom of particular keys not working. Refer to 
pages 3-1, 3-2 of the 3151 Guide to Operations, Models 510, 610. 
Line drawing characters do not display
 
Line drawing characters not displayed is a result of a character mismatch 
between the host and the 3151.  3151 offers the following character sets: 
Special Graphics, PC 00437, PC 00850, ISO 8859/1.2.  Determine the character 
set defined in 3151 and determine what the host is expecting. 
3151 has extra blank lines
 
To get rid of extra blank lines, set "Auto LF = OFF" in the general setup 
menu, or from the host use "Set Control 3" command:  ESC " 9 = b 
Application is not displaying correctly
 
If an application is not displaying correctly, it could be that host 
commands do not match the 3151 settings.  3151 is set to IBM 3151 and host 
could be using DEC VT100, WYSE 50/50+. Use 3151 Transparency mode to determine 
what host is sending. 
Cannot redefine function keys
 
With model 510/610, redefining function keys is not supported. 
Constant beep
 
A constant beep may occur if you are using a cartridge with model 110. 
Cartridges are not supported with this model. 
Screen is wavy
 
If the screen is wavy, change the refresh rate to between 50 and 60 hertz. 
Press Ctrl-Shift-Hold.  3151 displays keyboard test pattern. Press Ctrl-F10. 
3151 displays A or B (refresh rate). Press F1 to toggle between A or B. Power 
off and on 3151. 
3151 displays "HJ"s in CATIA
 
CATIA supports VT100 emulation, but the IBM 3151 is set to IBM 3151 mode. 
The VT100 commands are not compatible with IBM 3151 mode. Therefore, 3151 
requires either IBM/DEC or Connectivity cartridge which offers VT52, VT100 or 
VT200. 
3151 backspace key is not working
 
If the backspace key does not seem to work: 
 
- When using DEC emulation, the Backspace key is a DEL key, as it is on a DEC 
terminal. 
- It could be that the application is causing the unexpected result. 
Setup values of one 3151 does not match other 3151
 
The 3151 offers many models and eight cartridges with over 20 emulations, so 
the setup value could differ among 3151s. Compare the machine mode of each 
3151.  Possibilities include: 
 
- Could have two different models 110 versus 310/410 versus 510/610. 
- Perhaps one 3151 has a cartridge and the other does not. 
- Both 3151s have cartridges, but they may be different types of cartridges: 
IBM/DEC, Expansion, Connectivity, or WYSE 50/50+. 
- Both 3151s have the same cartridge, but the machine mode is not set the 
same. 
Review your 3151 documentation. 
 
 
- How can I identify the model? 
 
- Model 110 
   Display         Green
     Part Numbers  81X4500, 09F3483
   Keyboard        84-key ASCII
     Part Number   1392980
   Machine Modes   3151, 10 ASCII Emulations
- Model 310 
   Display         Green
     Part Numbers  81X4501 09F3484
   Keyboard        102-key ASCII
     Part Number   1392595
   Machine Modes   3151, 3101, 10 ASCII Emulations
- Model 410 
   Display         Amber-Gold
     Part Number   81X4511 09F3485
   Keyboard        102-key ASCII
     Part Number   1392595
   Machine Modes   3151, 3101, 10 ASCII Emulations
- Model 510 
   Display         Green
     Part Number   38F5101
   Keyboard        101-key PS/2
     Part Number   1395162
   Machine Modes   3151 PC, 3151 PC II and 925 PC
- Model 610 
   Display         Amber-Gold
     Part Number   38F5104
   Keyboard        101-key PS/2
     Part Number   1395162
   Machine Modes   3151 PC, 3151 PC II and 925 PC
 
- How can I change the cursor style (block, underscore, blink, none)? 
 
- Model 110:  Press Ctrl-F9. 
- Model 310, 410:  No cartridge, press Ctrl-8 (numeric keypad). 
- Model 310, 410:  Connectivity Cartridge, user setup menus. 
- Model 310, 410:  Expansion Cartridge, user setup menus. 
- Model 310, 410:  IBM/DEC cartridge, press Ctrl-8 (numeric keypad). 
- Model 310, 410:  WYSE cartridge, press Ctrl-8 (numeric keypad). 
- Model 510, 610:  User setup menus or the "Set Cursor Type" command (ESC F 
pa). 
 
 
- How can I change the status line (none, machine status, host message)? 
From the host, change it from Write Host Message, Display Host Message, and 
Display Machine Status.  From the user, change it by keyboard or user setup. 
  
- Model 110:  Press Ctrl-F10. 
- Model 310, 410:  No cartridge, press Ctrl-9 (numeric keypad). 
- Model 310, 410:  Connectivity Cartridge, user setup menus. 
- Model 310, 410:  Expansion Cartridge, user setup menus. 
- Model 310, 410:  IBM/DEC cartridge, press Ctrl-8 (numeric keypad). 
- Model 310, 410:  WYSE cartridge, press Ctrl-8 (numeric keypad). 
- Model 510, 610:  User setup menus. 
  
 
- How can I get a RS422 interface on the Main Communications Port? 
 
- Model 110:  Not available. 
- Model 310, 410:  Requires IBM/DEC, Connectivity, Expansion Cartridge. 
- Model 510, 610:  RS422 is included. 
 
 
- Does the auxiliary port support RS422 interface? 
No, it only supports RS232. 
 
- What is the difference between RS232 and RS422? 
 
- RS232 defines nine pins.  Two pins are used for Transmit and Receive Data 
(TD, RD).  RS422 defines five pins.  Four pins are used for Transmit and 
Receive date (TD+, TD-, RD+, RD-). 
- RS232C can attach 50-75 feet; RS232D can attach 200 feet; RS422 can attach 
4000 feet. 
 
 
- How can I change the function keys? 
 
- Models 110, 310, 410: From the host or by user setup (DEF F). 
- Models 510, 610:  Not available. 
 
 
- How many function keys are available on the 3151? 
 
- Model 110 
 
- 12 physical, 12 total (unshifted only) 
- Redefinable from host or user setup (DEF F). 
 
- Model 310/410 
 
- 12 physical, shiftable to 36 (unshifted, shift, ctrl-shift) 
- Redefinable from host or user setup (DEF F). 
 
- Model 510/610 
 
- 12 physical, shiftable to 36 (unshifted, shift, ctrl-shift) 
- Not redefinable 
 
 
 
- How can I reset/clear a function key to the default value? 
 
- From User setup - Press Ctrl-Clear key. 
- From Host - (ESC SP t) "Reset All Default Default Function Keys" 
 
 
- Can an input device be attached to the auxiliary port? 
 
- Model 110:  No, auxiliary port is unidirectional. 
- Model 310, 410, 510, 610: Yes, auxiliary port is bidirectional. 
 
 
- Can a key (setup, break, ctrl, etc.) be disabled? 
No, except with a keystopper under the keycap. 
 
- Can a key swap locations with another key? 
No. 
 
- Can I add a model 310, 410, 510, or 610 keyboard to a model 110 display? 
Cannot mix any combination of 84-, 101-, and 102-key keyboards. Keyboard 
must match video display. 
 
- How can I automatically dial a modem? 
With a connectivity cartridge or by assigning an unused function key. The 
cartridge requires six keystrokes; the unused function key requires two to 
three. 
 
- How can I activate or deactivate a printer from the keyboard? 
Press Ctrl-Trace key. 
 
- How can I display CAPS information? 
Turn on the status line. 
 
- How can I get 132 columns? 
 
- Model 110 supports 24X80 or 25X80. 
- Model 310, 410 supports 24X80, 25X80, 24X132, or 25X132. 
- Model 310, 410 Expansion Cartridge supports models 310, 410 base screen 
sizes, plus 28X80 or 28X132. 
- Model 510, 610 supports 24X80, 25X80, 24X132, or 25X132. 
 
 
- How can I change the screen size? 
From setup, or from the host using the "Create Viewport Command". 
 
   24 X 80        ESC SP r ! ! SP 8 " P
   25 X 80        ESC SP r ! ! SP 9 " P
   28 X 80        ESC SP r ! ! SP < " P (Expansion Cartridge)
   24 X 132       ESC SP r ! ! SP 8 $ D
   25 X 132       ESC SP r ! ! SP 9 $ D
   28 X 132       ESC SP r ! ! SP < $ D (Expansion Cartridge)
 
- Are communication cables included? 
No. 
 
- What is the command to turn printer on/off from the host? 
Begin/End Pass-Through Mode (DLE DC2 and DLE DC4). 
 
- Can 3151 be switched between 110 and 220 volts? 
No, each country has appropriate video display with proper power supply. 
 
- How can the 3151 display line drawing characters? 
Step A:  Assign G0/G1 using "Select Character Set" command. 
 
Step B:  Select either G0 or G1 by: 
  
- 8 bit mode:  Turn on most significant bit. 
- 7 bit mode:  Use SO/SI ASCII control characters. 
 
- What character sets are available? 
 
- Model 110/310/410 - US ASCII and IBM Special Graphics 
- Model 510/610 - US ASCII, IBM Special Graphics, PC Code Page 00437, PC Code 
Page 00850. 
 
 
- What is the sex of the main and auxiliary ports? 
Both are 25-pin D-Shell female. 
 
- Which port is the main communication port? 
If you look at the back of the 3151, the main port is on the right-hand 
side, closest to the edge.  The auxiliary port is closest to the power cord. 
 
- How can I get dual session? 
With a Cartridge for Connectivity, by selecting "Dual Session by Dual Port" 
in "SESSION ASSIGNMENT" setup menu. 
 
- Are there any keyboard extension cables available? 
IBM does not offer or support any changes between the keyboard and display 
elements. 
 
- Is there any support of the 7695 Bar Code Reader that is placed between 
keyboard and display elements? 
Only the model 510/610 supports the 7696 Bar Code Reader.  OEM products are 
available that can be placed between the keyboard and display element; however, 
IBM does not support these OEM devices. 
 
- Does the 3151 offer a CRT Saver/Screen Saver? 
Yes, CRT is selectable between "No Save" or 15 minutes.  The CRT is 
selectable by the user in the General Setup menu, or by the host with the "Set 
Control 2" command. 
 
- What is the difference between 8J0140 (3151-805) and 8J0141 (AS/400 
Cartridge)? 
When 8J0141 (Cartridge/Keycap Kit) is installed on a 3151 Model 310, the 
3151 is the same a 3151-805.  The 3151-805 is available only in green.  8J0141 
can be also installed on 3151 Model 410 (amber-gold).  8J0140 is for new 
installations, and 8J0141 is for existing 3151-31/41 installed. 
 
- Is a tilt/swivel stand included? 
Yes, effective 05/89. 
 
- Does 3151 have a data entry keyboard? 
No. 
 
   GENERAL
  
   Machine Mode      IBM 3151
   Screen              Normal
   Row and Column     24 X 80
   Scroll                Jump
   Auto LF                Off
   CRT Saver              Off
   Line Wrap               On
   Message Type   STATUS LINE
   Forcing Insert        Both
   Tab                  Field
   Term. ID _________________
 
   COMMUNICATIONS
 
   Operating Mode        Echo
   Line Speed (bps)      9600
   Line Control         IPRTS
   Word Length (bits)       8
   Parity                  No
   Stop Bit                 1
   Turnaround Character    CR
   Break Signal (ms)      500
   Send Null Suppress      On
 
   KEYBOARD
 
   Enter                 Send
   Return            New Line
   New Line                CR
   Send                  Line
   Insert Character     Space
  
   
Common Problems and Questions About 3151 Terminals : 3151.32.zap ITEM: FAX
Dated: 1999/09/28~00:00 Category: zap
This HTML file was generated 2001/03/08~16:05:57
Comments or suggestions?
Contact us