C327 INTR

Error Description: C327 ERROR INTERRUPT

This error is logged by the 3270 Connection Adapter device driver when the control unit detects an error condition, the error is corrected, or the control unit is not responding because the coaxial (COAX) cable is disconnected.

DETAIL DATA

Reason Code This field indicates where the error occurred. Most of the errors are described in the publication 3270 Information Display System: 3274 Control Unit Description and Programmer's Guide. The following errors could also occur:
603
Control unit is not responding (COAX disconnected).
670
Control unit is not responding (COAX disconnected).
671
Adapter card not functioning correctly.
774
Session is not available.
Line Address The number of the session which had the error (session numbers start with 1).

C327 START

Error Description: C327 START ERROR

This error is logged by the 3270 Connection Adapter device driver when a session with a host could not be started.

DETAIL DATA

Reason Code Reason the session could not be started. The following errors could also occur:
8200
Control unit is not responding (COAX disconnected).
8300
Adapter card is not functioning correctly.
8303
SNA control unit--not supported.
8306
Control unit does not support extended AEDV status.
8601
Session is not available.
Line Address The number of the session which had the error (session numbers start with 1).