IBM Books

Diagnosis Guide


Error information

AIX Error Log

Per Node Key Management logs errors to the AIX Error Log. Use the AIX errpt command to view the error logs. A helpful invocation of the errpt command is:

errpt -a -N spnkeyman
This shows a complete listing of all errors logged by spnkeyman.

An example of one error logged by spnkeyman is:

            LABEL:                SPNKEYMAN_ERROR104
            IDENTIFIER:           C0A5D912
                 
            Date/Time:            Tue Oct 26  10:55:49
            Sequence Number:      3482
            Machine Id:           000101774C00
            Node Id:              c166n08
            Class:                S
            Type:                 PEND
            Resource Name:        spnkeyman
 
            Description
            UNDETERMINED ERROR
 
            Probable Causes
            REVIEW EVENT DETAIL FOR PROBABLE CAUSE
 
            Failure Causes
            SOFTWARE SUBSYSTEM
 
                     Recommended Actions
                     REVIEW DETAILED DATA
                     PERFORM PROBLEM DETERMINATION PROCEDURES
                     CORRECT THEN RETRY OFFENDING SOFTWARE COMPONENT
                     IF PROBLEM PERSISTS, CONTACT APPROPRIATE 
                                         SERVICE REPRESENTATIVE 
 
             Detail Data
             DETECTING MODULE
             LP=PSSP, Fn- spnkeymand.c, SID=1.6, l#=582,
              
             DIAGNOSTIC EXPLANATION
             spsec_keyman_get_expiration error for ssp/sp_configd. err=44
             2502-618 The required keyfile was not found:
                 /spdata/sys1/keyfiles/ssp/c166n08.ppd.pok.ibm.com               

Underlying authentication mechanisms and libraries may have other NLS restrictions. Per Node Key Management displays messages received from these mechanisms without translating them. Consult necessary documentation for this authentication mechanisms for more information.

The AIX error log can wrap, and the error information can be overwritten. Periodically check the log for Per Node Key Management errors and, if any, save the information to a file.

This table lists the AIX error log templates for Per Node Key Management. All entries are of type PEND, meaning that loss of availability of a device or component is imminent.

Table 48. AIX Error Log templates for Per Node Key Management

Label Error ID Description
SPNKEYMAN_ERROR100 7A1D698B Explanation: Generic initialization error.

Details: Program initialization failed.

SPNKEYMAN_ERROR101 E06378AD Explanation: Effective userid is not root.

Details: The user starting the daemon was not using the root userid. The user is not authorized.

SPNKEYMAN_ERROR102 789B9E1E Explanation: Thread creation failure.

Details: The daemon could not create necessary threads.

SPNKEYMAN_ERROR104 C0A5D912 Explanation: Generic SP security or DCE error.

Details: An underlying library call or subsystem error. Messages may be passed through PNKM or issued by PNKM, if possible, concerning this error.


[ Top of Page | Previous Page | Next Page | Table of Contents | Index ]