Sending jobs from PSF/AIX to Windows NT server.

ITEM: RTA000160296



Q:                                                                              
Topic thread:                                                                   
Printer Systems (PRINT - NA/ATS)                                                
 PSF/AIX                                                                        
                                                                                
Hi,                                                                             
                                                                                
                                                                                
We have a customer that is using PSF6000 to print some applications. Now        
                                                                                
 they have a NP12 without IPDS and this printer is connected in Windows         
NT by parallel cable. This Windows is a printer server and is receiving         
data from AIX without pass for any driver. In AIX they created a remote         
queue and in PSF they created the queue based in AIX remote queue. They         
tried to print from PSF but they had problems with fonts. The variable         
data is printing out of the right position. They changed the fonts and          
they had a little better printing but it isn't perfect yet. The ainbe           
is transforming this job in PCL 5, is there any PTF that I should               
verify for this case?? Do you have any suggestion for this problem???           
                                                                                
                                                                                
Thank you in advance                                                            
A:                                                                              
One suggestion I would make is to create your AIX remote queue as a             
"remote queue with local filtering".  What this does is formats the             
data on the RS/6000 (i.e. runs it through the AIX Virtual printer)              
and then sends the data to the NT server in "passthrough" mode, telling         
the NT server not to do anything to the data but just print it.                 
                                                                                
This works well for other LPD type print servers.                              
                                                                                
To do this you would do:                                                        
                                                                                
smitty mkpq                                                                     
   Local filtering before sending to print server                               
     IBM                                                                        
       ibm4312   IBM Network Printer 12   (**This "driver" must be              
                 installed on the RS/6000 for this option to show up.)          
       Then put the name of the queue in the PCL 5E Emulation field.            
                                                                                
Once this is created, you change your PSF AIX-Defined queue's device            
options to point to this new AIX queue. You will need to "bounce" the           
PSF queue for the changes to take place:                                        
                                                                                
psfctl -dtu PSF_QNAME                                                          
                                                                                
I hope this helps.  Thank you.                                                  
                                                                                