System Date/Time Changes are Lost After Reboot
Environment
OS Level: between AIX Versions 4.1.4.20 and 4.1.5.2 
Type/Model. The following models with bos.rte.up fileset 
are affected:
7006 all models (41T/41W/42T/42W) 
7009 all models (c10/c20) 
7011 models 25x (250/25T/25W only)
Problem
All files dates change to 1970 after restoring mksysb tape. 
Changes to the system clock do not persist through a reboot on 
some models. System date/time changes are lost after reboot since 
the hardware real-time clock is not being set.
Solution
The APAR IX64227 addresses this problem and should be installed.
System Date/Time changes are Lost After Reboot:   ITEM: FAX
Dated: 2000/04/28~00:00 Category: anz
This HTML file was generated 2001/03/08~16:06:38
Comments or suggestions?