[ Previous | Next | Contents | Glossary | Home | Search ]
AIX Version 4.3 Problem Solving Guide and Reference

CXMA (128-port) Error Identifiers for the Error Log

CXMA_ERR_ASSRT

Error Description: Driver assert message.

DETAIL DATA

The 128-port device driver has detected an internal error. The Driver Line Number field contains the line number in the device driver where the error occurred. Contact your service representative.

CXMA_CFG_FEPOS

Error Description: An error occurred executing the 128-port adapter FEPOS microcode.

DETAIL DATA

Perform the "Hardware Diagnostics" or contact your service representative.

CXMA_CG_BIOS

Error Description: An error occurred executing the 128-port adapter BIOS microcode.

DETAIL DATA

Perform the "Hardware Diagnostics" or contact your service representative.

CXMA_CFG_RST

Error Description: The 128-port adapter did not respond to a hardware reset.

DETAIL DATA

Perform the "Hardware Diagnostics" or contact your service representative.

CXMA_ADP_FAIL

Error Description: The 128-port device driver has detected an unrecoverable error communicating with the adapter.

DETAIL DATA

Perform the "Hardware Diagnostics" or contact your service representative.

CXMA_CFG_MEM

Error Description: The 128-port adapter memory address in the DDS structure passed from the cfgcmxa configuration method to the driver configuration entry point is not valid. This could be caused by a corrupted ODM database.

DETAIL DATA

Contact your service representative.

CXMA_CFG_PORT

Error Description: The 128-port adapter I/O port address in the DDS structure passed from the cfgcmxa configuration method to the driver configuration entry point is not valid. This could be caused by a corrupted ODM database.

DETAIL DATA

Contact your service representative.

CXMA_CFG_MTST

Error Description: The 128-port device driver detected an error during a memory test of the 128-port adapter's dual-ported memory.

DETAIL DATA

Perform the "Hardware Diagnostics" or contact your service representative.

CXMA_CFG_TALLOC

Error Description: The 128-port device driver detected an error attempting to allocate a trb timer structure.

DETAIL DATA

Contact your service representative.

CXMA_IO_ATT

Error Description: The 128-port device driver detected an error attempting to attach to I/O memory.

DETAIL DATA

Perform the "Hardware Diagnostics" or contact your service representative.

CXMA_MEM_ATT

Error Description: The 128-port device driver detected an error attempting to attach to bus memory.

DETAIL DATA

Perform the "Hardware Diagnostics" or contact your service representative.

d
[ Previous | Next | Contents | Glossary | Home | Search ]