AIX Version 4.3 Messages Guide and Reference

List of Three-Digit Display Values: 300-325

Display Value 301

Explanation Irrecoverable error. Flash Utility ROM test failed or checkstop occurred.
System Action The system halts.
User Action See "Booting Problems" for recovery procedures. If those procedures fail to correct the problem, record SRN 101-201 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 302

Explanation Flash Utility ROM is prompting user to move the keyswitch to Service position to select an optional Flash update.
System Action LED 302 will appear only if the keyswitch is secure. LED 302 will display for a maximum of 4 seconds.
User Action If you wish to perform a Flash update, then the keyswitch should be moved to the Service position during the 4 seconds that LED 302 is displayed. If the key is moved to the Service position, then LED 303 will be displayed for 4 seconds. This signals the user to press the Reset button to initiate the optional Flash update.

Display Value 303

Explanation Flash Utility ROM is prompting the user to press the Reset button to initiate an optional Flash update.
System Action LED 303 will display for a maximum of 4 seconds.
User Action If you wish to initiate a Flash update, then the Reset button should be pressed during the time that LED 303 is displayed (see LED 302).

Display Value 304

Explanation Progress indicator. I/O planar test started.
System Action If the I/O planar test is not successful, the system halts.
User Action If the system halts, record the SRN 101-290 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 305

Explanation Progress indicator. Standard I/O planar power-on self-test is running.
System Action If an irrecoverable error occurs, the system halts.
User Action If the system halts, record the SRN 101-291 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 306

Explanation Progress indicator. Attempting to load Flash update code from the standard I/O planar-attached device.
System Action The system retries.
User Action Insert a Flash update diskette in the diskette drive. If the Flash update code fails to load, then record SRN 101-252 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 307

Explanation System model number could not be determined.
System Action The system halts.
User Action Record the SRN 101-297 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 308

Explanation Progress indicator. TCW memory is bad.
System Action If an irrecoverable error occurs, the system halts.
User Action If the system halts with this value displayed, record the SRN 101-290 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 309

Explanation Progress indicator. The Flash Utility ROM passed control to a Flash update boot image.
System Action If control transfer was not successful, the system halts.
User Action If the system halts, record the SRN 101-299 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 311

Explanation IPL ROM CRC miscompare occurred during system restart.
System Action The system halts.
User Action Record SRN 101-211 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 312

Explanation RAM power-on self-test found processor to be bad.
System Action The system halts.
User Action If the system halts with this value displayed, record SRN 101-212 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 313

Explanation RAM power-on self-test failed. Memory cannot be configured because the system could not detect any good memory.
System Action The system halts.
User Action If the system halts with this value displayed, record SRN 101-213 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 314

Explanation An I/O planar failure has been detected. The power status register, the time-of-day clock, or NVRAM on the I/O planar has failed.
System Action The system halts.
User Action Record SRN 101-214 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 315

Explanation Progress indicator. The level of voltage supplied to the system is too low to continue a system restart.
System Action The system monitors the voltage level. When the voltage is correct, the system continues with its system restart.
User Action Check that the power cable is correctly attached to the system and to the electrical outlet. Check that power is available at the electrical outlet. If these actions do not correct the problem, record SRN 101-215 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 318

Explanation Progress indicator. RAM power-on self-test is testing for 1MB of good memory.
System Action If at least 1MB of good memory is not found, the system halts.
User Action If the system halts with this value displayed, record SRN 101-218 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 319

Explanation Progress indicator. RAM power-on self-test bit map is being generated.
System Action If an irrecoverable error occurs while generating the bit map, the system halts.
User Action If the system halts with this value displayed, record SRN 101-219 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 322

Explanation CRC of Flash image on diskette failed. No Flash update performed.
System Action If the CRC of the Flash update image from a diskette fails, then the system halts.
User Action The Flash update diskette is corrupted. Report the problem to your software service organization, and then stop. You have completed these procedures.

Display Value 323

Explanation Progress indicator. Current Flash image is being erased.
System Action The existing Flash image is being erased. This LED will display for approximately 5 seconds.
User Action Record SRN 101-211 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 324

Explanation CRC of new Flash image failed after update was performed (Flash image is corrupted).
System Action If the CRC of a new Flash image fails after it has been written, then the system halts.
User Action Record SRN 101-211 in item 4 on the Problem Summary Form. Report the problem to your hardware service organization, and then stop. You have completed these procedures.

Display Value 325

Explanation Progress indicator. Flash update successful and complete.
System Action When a Flash update has completed successfully, the system will halt.
User Action When the system halts displaying this value, turn off the system and remove the Flash update diskette from the diskette drive. Then turn on the system and reboot.