Input-Inhibited Field Error Codes |
|
Error Code |
Explanation |
User Response |
610 |
Fatal communication check |
Ensure that the coaxial cable is securely connected to the 3174/3274 control unit. |
670 |
Hardware time out |
Record the information and call your system representative. |
671 |
Device initialization error |
Record the information and call your system representative. |
672 |
HCON internal error |
Record the information and call your system representative. |
673 |
HCON internal error |
Record the information and call your system representative. |
674 |
Hardware error |
Record the information and call your system representative. |
675 |
HCON internal error |
Record the information and call your system representative. |
676 |
HCON internal error |
Record the information and call your system representative. |
677 |
Device address already enabled |
Record the information and call your system representative. |
678 |
Device address not enabled |
Record the information and call your system representative. |
679 |
HCON internal error |
Record the information and call your system representative. |
680 |
HCON internal error |
Record the information and call your system representative. |
681 |
HCON internal error |
Record the information and call your system representative. |
683 |
Selective reset issued |
The host has issued a selective reset. Consult your local host administrator. |
684 |
Power-on reset in progress |
Press the RESET key to clear the error. Continue with the host session. |
687 |
The adapter has shut down |
Record the information and call your system representative. |
688 |
HCON internal error |
Record the information and call your system representative. |
689 |
HCON internal error |
Record the information and call your system representative. |
690 |
HCON internal error |
Record the information and call your system representative. |
703 |
Unsupported request received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
705 |
SNF field of transmission header out of sequence |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
706 |
Command chaining error |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
707 |
Bracket state violation |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
708 |
Data traffic not yet started |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
709 |
Half-duplex protocol violation |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
711 |
Session limit exceeded |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
713 |
Session already bound |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
714 |
Session not bound |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
715 |
Session not activated |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
716 |
BIND parameter list too short |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
717 |
BIND support level not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
718 |
BIND PLU protocol not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
719 |
BIND SLU protocol not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
720 |
BIND Common protocol not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
723 |
BIND LU type not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
724 |
BIND screen size not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
725 |
BIND cryptography not supported |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
726 |
Negative response received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
727 |
Exception request received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
728 |
Read command with end bracket (EB) or not in licensed internal code (LIC) + CD |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
729 |
Read Partition received while the device was in retry state |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
731 |
BIND inbound maximum RU size not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
732 |
BIND outbound maximum RU size not valid |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
750 |
Not valid 3270 command received |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
751 |
Not valid character set value for SFE, MF, or SA order |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
752 |
Address out of range for SBA, RA, or EUA order |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
753 |
Data follows RM, RMA, RB, or EAU command; RA has not valid character; not valid attribute value or type for SFE, MF, or SA; not valid parameter for SA (SCS) |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
755 |
Not valid 3270 order received or not valid DBCS character code received. |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
756 |
SF type not valid or unsupported |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
759 |
Error in SF length |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
761 |
Not valid PID value for SF |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
769 |
HCON internal error |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
771 |
Not valid command in SF |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
791 |
Not valid SHF or SVF parameter (SCS) |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
792 |
Not valid SLD parameter (SCS) |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
793 |
Spooling print job failed (SCS) |
Record the information and contact the host system programmer. |
797 |
SO/SI are not in correct pair |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
798 |
SO/SI are received in DBCS field or GE is received in DBCS field or DBCS subfield |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |
799 (SBCS) |
HCON internal error |
Record the information and call your system representative. |
799 (DBCS) |
Start address points at DBCS low byte, not valid character attribute value in DBCS field or DBCS subfield, or not valid stop address |
Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer. |