Operator Information Area (OIA)

When using the 3270 Host Connection Program, the last line on the display screen is the Operator Information Area (OIA). The OIA provides system and session status information in Operator Information Area fields. Columns 9 to 17 of the OIA fields contain the Input-Inhibited error codes for HCON.

Operator Information Area Fields

System and session status information is located in specific fields in the OIA. The fields and descriptions are:

Column Description
1 to 3 Readiness and System Connection Information field
9 to 17 Input-Inhibited field
21 to 27 Communication-Check Reminder field
38 Insert Mode field
51 to 56 Internal-Error Indicator field
58 Session Name field
59 Colon Separator field
60 to 79 Session Use field

The following tables contain the symbols used in the fields, the column where the symbols start, and a description of its function.

Readiness and System Connection Information Field
Column Symbol Description
1 4 3274 Control unit and session are ready.
1 S 3274 Control unit and session are ready.
1 I 4361 Integrated workstation adapter and session are ready.
1 N 9370 Workstation subsystem controller and session are ready.
1 2 SNA Node T2.1 attached standalone session running through SDLC/Token-Ring/X.25/Ethernet is ready.
1 T TCP/IP session is ready.
2 A The control unit is connected to the host using a non-SNA session.
2 B The control unit is connected to the host using SNA.
3 " The session is working with the host application (for SNA in LU-LU session and for non-SNA).
3 < The session is communicating with the host system SSCP (SNA SSCP-LU session only).
3 ? The session is not owned (SNA only).
Input-Inhibited Field
Column Symbol Description
9 X ( ) The host system needs time to perform a function.
9 X SYSTEM The host system locked the keyboard.
9 X MACHnnn Indicates a hardware problem. The machine check number is in the range of 201 to 269, 290 to 299, or 601 to 699. Equivalent to the 3278/79 error indicators: X, backslash, box and backslash, box.
9 X - +z_nnn Indicates a communication line problem. The communication number is in the range of 501 to 599 or 610. This is equivalent to the 3278/79 error indicator: X followed by the broken communication symbol.
9 X PROGnnn A programming error is detected in the data from the host. The error number is in the range of 401 to 499 or 701 to 799. This is equivalent to the 3278/79 error indicator X PROG.
9 X ?+ The last input is not accepted.
9 X -f The requested function is not available.
9 X < 0 > The cursor must be moved. It is in a protected field and an attempt has been made to enter, insert, erase, or delete a character.
9 X 0 > An attempt has been made to enter more data into a field than can fit into it.
9 X -S The symbol entered is not available.

For a list of input-inhibited field error codes and suggested responses, see "Input-Inhibited Field Error Codes for the HCON OIA".

Insert Mode Field
Column Symbol Description
38 ^ Insert mode is on.
Internal Error Indicator Field
Column Symbol Description
51 ERRnnn Indicates an internal emulator error. nnn is the error number. Record the error number and call the system representative.
Session Name Field
Column Symbol Description
58 a to z The session name specified in the session profile from configuration.
Session Use Field
Column Symbol Description
60 session use A character string describing the session. The string is specified in the session profile from configuration.
Note: For SNA standalone sessions, the SNA Logical Connection Profile name is right-justified in the session use field, if sufficient space in the field exists.

Input-Inhibited Field Error Codes for the HCON OIA

This table lists possible input-inhibited field error codes, an explanation of the problem, and suggested responses.

Note: This list of error codes represents the events most likely to occur. For a complete list of all possible 3270 errors, see the Control Unit Reference Summary, order number GX20-1878.
Input-Inhibited Field Error Codes
Error Code Explanation User Response
610 Fatal communication check Ensure that the coaxial cable is securely connected to the 3174/3274 control unit.
670 Hardware time out Record the information and call your system representative.
671 Device initialization error Record the information and call your system representative.
672 HCON internal error Record the information and call your system representative.
673 HCON internal error Record the information and call your system representative.
674 Hardware error Record the information and call your system representative.
675 HCON internal error Record the information and call your system representative.
676 HCON internal error Record the information and call your system representative.
677 Device address already enabled Record the information and call your system representative.
678 Device address not enabled Record the information and call your system representative.
679 HCON internal error Record the information and call your system representative.
680 HCON internal error Record the information and call your system representative.
681 HCON internal error Record the information and call your system representative.
683 Selective reset issued The host has issued a selective reset. Consult your local host administrator.
684 Power-on reset in progress Press the RESET key to clear the error. Continue with the host session.
687 The adapter has shut down Record the information and call your system representative.
688 HCON internal error Record the information and call your system representative.
689 HCON internal error Record the information and call your system representative.
690 HCON internal error Record the information and call your system representative.
703 Unsupported request received Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
705 SNF field of transmission header out of sequence Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
706 Command chaining error Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
707 Bracket state violation Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
708 Data traffic not yet started Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
709 Half-duplex protocol violation Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
711 Session limit exceeded Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
713 Session already bound Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
714 Session not bound Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
715 Session not activated Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
716 BIND parameter list too short Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
717 BIND support level not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
718 BIND PLU protocol not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
719 BIND SLU protocol not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
720 BIND Common protocol not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
723 BIND LU type not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
724 BIND screen size not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
725 BIND cryptography not supported Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
726 Negative response received Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
727 Exception request received Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
728 Read command with end bracket (EB) or not in licensed internal code (LIC) + CD Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
729 Read Partition received while the device was in retry state Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
731 BIND inbound maximum RU size not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
732 BIND outbound maximum RU size not valid Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
750 Not valid 3270 command received Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
751 Not valid character set value for SFE, MF, or SA order Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
752 Address out of range for SBA, RA, or EUA order Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
753 Data follows RM, RMA, RB, or EAU command; RA has not valid character; not valid attribute value or type for SFE, MF, or SA; not valid parameter for SA (SCS) Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
755 Not valid 3270 order received or not valid DBCS character code received. Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
756 SF type not valid or unsupported Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
759 Error in SF length Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
761 Not valid PID value for SF Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
769 HCON internal error Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
771 Not valid command in SF Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
791 Not valid SHF or SVF parameter (SCS) Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
792 Not valid SLD parameter (SCS) Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
793 Spooling print job failed (SCS) Record the information and contact the host system programmer.
797 SO/SI are not in correct pair Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
798 SO/SI are received in DBCS field or GE is received in DBCS field or DBCS subfield Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.
799 (SBCS) HCON internal error Record the information and call your system representative.
799 (DBCS) Start address points at DBCS low byte, not valid character attribute value in DBCS field or DBCS subfield, or not valid stop address Press the RESET key to clear the error. If the problem continues, record the information and contact the host system programmer.