When a network installation is in progress, the LED/LCD for the nodes
involved show various values. These values indicate the installation
stage.
These values are periods of high volumes of network traffic and are only
a problem on a node when the value does not change for a very extended period
of time. You can use Table 9 as a debugging tool when a node is stuck on a specific
LED/LCD value.
Time (min:sec)
| LED/LCD value
| Description
|
0:00
|
|
|
| 124
| BIST started a CRC check on the OCS area of NVRAM.
|
| 151
| BIST started AIPGM test code.
|
| 214
| Power status register failed.
|
| 219
| Generating RAM POST bit map.
|
| 291
| Running standard I/O POST.
|
| 200
| Attempting IPL with key in secure position.
|
| 102
| BIST started following power-on reset.
|
| 153
| BIST started ACLST test code.
|
0:30
|
|
|
| 154
| BIST started AST test code.
|
| 100
| BIST completed successfully; control was passed to IPL ROS.
|
| 219
| Generating RAM POST bit map.
|
| 292
| Running SCSI POST.
|
1:00
|
|
|
| 291
| Running standard I/O POST.
|
| 262
| No keyboard connected to the system.
|
| 260
| Displaying information on the display console.
|
1:30
|
|
|
| 231
| Attempting a normal mode IPL from Ethernet specified in IPL ROM.
|
2:30
|
|
|
| Blank
|
|
| 606
| Running the if_config command to bring up network
interface.
|
| 610
| Attempting to NFS mount a remote file system.
|
| 299
| IPL ROM passed control to the loaded program code.
|
| 608
| Attempting to tftp the .info file from client's
SPOT server.
|
| 612
| Accessing remote configuration files.
|
| 622
| Returning control to the /sbin/rc.boot program.
|
| 520
| Running bus configuration.
|
| 890
| SCSI-2 differential fast/wide adapter.
|
| 620
| Updating special device files.
|
3:00
|
|
|
| 890
| SCSI-2 differential fast/wide adapter.
|
| 570
| Configuring virtual SCSI devices.
|
3:30
|
|
|
| 622
| Returning control to the /sbin/rc.boot program
|
4:00
|
|
|
| 811
| Identifying or configuring processor complex.
|
| Blank
|
|
| 570
| Configuring virtual SCSI devices.
|
| 727
| Identifying or configuring unknown asynchronous device.
|
| 538
| The configuration manager is invoking a configuration method.
|
| 622
| Returning control to the /sbin/rc.boot program.
|
| c40
| Restoring configuration files.
|
8:00
|
|
|
| c42
| Extracting data from diskette.
|
| c33
| Selecting a tty terminal attached to serial ports S1 or S2.
|
| c44
| Initializing installation database with target disk information.
|
8:30
|
|
|
| c46
| Normal installation processing.
|
| Blank
|
|
9:00
|
|
|
| c50
| Creating root volume group on target disks.
|
| c46
| Normal installation processing.
|
10:30
|
|
|
| c54
| Installing either BOS or additional packages.
|
19:00
|
|
|
| c52
| Changing from RAM environment to disk environment.
|
21:30
|
|
|
| c46
| Normal installation processing.
|
| 570
| Configuring virtual SCSI devices.
|
22:00
|
|
|
| c46
| Normal installation processing.
|
| 731
| Identifying or configuring PTY.
|
| 539
| The configuration method has terminated, returning to config.
|
| 811
| Identifying or configuring processor complex.
|
| 538
| The configuration manager is invoking a configuration method.
|
| 570
| Configuring virtual SCSI devices.
|
22:30
|
|
|
| Blank
|
|
23:00
|
|
|
| u78
| Running remote commands to complete node processing on boot/install
server.
|
| u60
| Creating /etc/ssp/server_name and updating
/etc/hosts.
|
| u68
| Copying kerberos realms file from boot/install server.
|
| u59
| Running config_node to define adapters.
|
27:00
|
|
|
| u65
| SSP completing the install/customize/maint. Issuing
shutdown.
|
27:30
|
|
|
| c46
| Normal installation processing.
|
28:00
|
|
|
| 292
| Running SCSI POST.
|
| 298
| Attempting a software IPL.
|
| 291
| Running standard I/O POST.
|
| 299
| IPL ROM passed control to the loaded program code.
|
| Blank
|
|
| 890
| SCSI-2 differential fast/wide adapter.
|
| 820
|
|
| 538
| The configuration manager is invoking a configuration method.
|
| 570
| Configuring Virtual SCSI devices.
|
28:30
|
|
|
29:00
|
|
|
| 551
| Running IPL varyon.
|
| 517
| Mounting client remote file system during network IPL.
|
29:30
|
|
|
| 553
| IPL phase 1 is complete.
|
| 570
| Configuring virtual SCSI devices.
|
| 538
| The configuration manager is invoking a configuration method.
|
| c33
| Selecting a tty terminal attached to serial ports S1 or S2.
|
30:00
|
|
|
| Blank
|
|
33:00
|
|
|
| 762
| Running SSP configuration method for SP Switch Adapter
|
34:00
|
|
|
| 570
| Configuring virtual SCSI devices.
|
| 538
| The configuration manager is invoking a configuration method.
|
34:30
|
|
|
| Blank
|
|