9.366 bytes

System Support Disks

Document ID: BBOD-3MCHT3

TP 365X/XD,380,385,560,600,755,760,770 - Infrared Driver Package for Windows NT 4.0

Applicable to: World-Wide


P/N
iii603ww

Description
This package provides the infrared communication driver to support IrDA (Infrared Data Association) 1.0 infrared communication protocol for Windows NT 4.0 users.

The driver supports point-to-point IR communication either with another ThinkPad computero r with a system equipped with an infrared port. This feature also supports the Generic (IrDA 1.0) mode up to 115000 BPS. This mode is used when communicating with other IBM ThinkPad computers.

Dial-Up Networking between the two computers through serial IR can be used as the Windows NT typical IR application.

This diskette enables or updates the infrared communication function of the following ThinkPad computers:
- ThinkPad 365X, 365XD
- ThinkPad 380, 380D, 380E, 380ED, 385D, 385ED, 380XD, 385XD, 380Z
- ThinkPad 560, 560E, 560X, 560Z
- ThinkPad 600, 600E
- ThinkPad 755CD, 755CDV, 755CE, 755CSE, 755CV, 755CX
- ThinkPad 760C, 760CD, 760L, 760LD, 760E, 760ED, 760EL, 760ELD, 760XD, 760XL, 765D, 765L
- ThinkPad 770, 770E, 770ED

P/N
iii603ww

Name & Size (bytes)
irtpgwnt.exe : 201579
irtpgwnt.txt : 4691

WWW URL(s)
ftp://ftp.pc.ibm.com/pub/pccbbs/mobiles/irtpgwnt.exe
ftp://ftp.pc.ibm.com/pub/pccbbs/mobiles/irtpgwnt.txt

The files contained in this document have been archived.

Double-click here for more information on the Archive process - .

The files can be obtained

From the IBM PC Company ftp site on the Internet at the address noted above,
(copy & paste the address into your Web Browser, or, if you are connected to an Internotes or Domino server, double-click on the address to hot-link directly to the URL. Note that the file type on the ftp site may be a different file type from the file originally attached to this document - eg .ZIP instead of .EXE)

From the Archive Database -
LN V3 - IBM PC Service Information Archive Database - CD1 1997
LN V4 - IBM PC Service Information Archive Database - CD1a 1997
- : or as indicated below:-

This document was archived on the database - PC Service Info Archive 1998/2 -- Replica ID : 802565E7004DC09A

Note: If the doclink below does not function properly, try using the preview doclink button on the action bar to access the archived document.

Disk Release Date:

19-10-98

Disk Version/Release:

1.12

Additional Information:

NOTE: This driver will now automatically extract to your hard drive. It will only extract under Windows 95, Windows 98, and Windows NT. The extraction process will NOT work with any other operating system.

Released Version
Version 1.00 Initial release
Version 1.10 Support for new models and a new function
Version 1.11 Support for new models and a problem fix
Version 1.12 Support for new models and a new function

Summary of Changes
1.10
-(New) Support for ThinkPad 380, 380D, 380E, 380ED, 385D, 385ED, 560E, 760XD, 760XL, 765D, 765L and 770.
-(New) Enabled automatic IR COM port assign. When IR COM port is by the ThinkPad Utility, IR COM port is reconfigured automatically. No registry update or change is required.

1.11
-(New) Support for ThinkPad 770E, 770ED, 600, 560X, 560Z, 380XD, 385XD and 380Z.
-(Fix) Fix the IR driver load problem when IBM AntiVirus 3.0 is installed on French version NT4.0.

1.12
-(New) Support for ThinkPad 770X, 600E
-(New) Support silent install ( install/s )

Installation instructions
To determine if you have to update the infrared communication driver or not, please refer to the "Summary of Changes" section.

Notice
If you install the Windows NT Service Pack after installing the IR driver, it is necessary to re-install the IR. This IR driver replaces the Microsoft driver serial.sys.

1. Log on the Windows NT with the administrator's password.
2. Extract the drivers onto the hard disk.
3. Click on Start -> Run...
4. Type C:\DRIVERS\WNT\INFRARED\INSTALL; then press Enter or click on OK to start the installation. The Windows NT Setup window appears.
5. Follow the instructions on the screen.
6. Shut down and restart the computer.

When the device driver is installed, the infrared port is configured as a COM1 (IRQ4/Base IO address 3F8h) serial device. This is the default setting.

If your IR port is not enabled as COM1, loading the infrared driver will fail. You know the driver failed to load if you see the Windows NT Event Viewer.

To enable the infrared port for COM1 on your computer, do the following:
1. Run ThinkPad Feature program and enable the IR device as COM1.
2. Shut down and restart the computer.

Changing the Infrared COM Port Number
When you need to use an IR port other than the default value for example, to change to COM2, do the following:

1. Run ThinkPad Feature program and change the IR device COM port number to COM2.
2. Shutdown and restart your computer.

After your computer is restarted, IR COM port will be changed.

Search Keywords

Disk Category

Infrared, Windows NT

Date Created

28-09-97

Last Updated

19-01-99

Revision Date

03-05-2000

Brand

IBM ThinkPad

Product Family

ThinkPad 365X/XD, ThinkPad 380, ThinkPad 380D, ThinkPad 380E, ThinkPad 380ED, ThinkPad 380XD, ThinkPad 385D, ThinkPad 385ED, ThinkPad 385XD, ThinkPad 560, ThinkPad 560E, ThinkPad 560X, ThinkPad 600, ThinkPad 755CE/CSE, ThinkPad 755CX, ThinkPad 755CV, ThinkPad 755CD, ThinkPad 755CDV, ThinkPad 760C, ThinkPad 760E, ThinkPad 760CD, ThinkPad 760L/LD, ThinkPad 760ED, ThinkPad 760XD, ThinkPad 760EL/ELD, ThinkPad 760XL, ThinkPad 765L, ThinkPad 765D, ThinkPad 770, ThinkPad 770E/ED, ThinkPad 380Z, ThinkPad 560Z, ThinkPad 770X, ThinkPad 600E

Machine Type

2635, 2640, 2645, 9546, 9547, 9548, 9549, 2625, 9545, 2636, 2641, 2646, 9544

Model

All

TypeModel

Retain Tip (if applicable)

Reverse Doclinks
and Admin Purposes