All Documents by Product Family / Doc TypeUpdatedDoc_Id
ServeRAID
Parts Information
ServeRAID 3L - Locations21-05-99MCGN-44LQ66
ServeRAID 3L - Technical Specifications08-04-99DDSE-44BNUT
ServeRAID 3H - Technical Specifications08-04-99DDSE-44BNCF
ServeRAID - Diagnostics15-03-99MCGN-44HNSE
ServeRAID - General Checkout15-03-99MCGN-44HN6A
ServeRAID - Symptom-to-FRU Index15-03-99MCGN-44JQU7
ServeRAID 3H - Locations15-03-99MCGN-44LPX9
ServeRAID - Channel Record Table15-03-99MCGN-44LQBG
ServeRAID - POST (ISPR) Error Procedures15-03-99MCGN-44JJUG
ServeRAID - Recovery Procedures for DDD Drives15-03-99MCGN-44PLKD
ServeRAID 3L - Configuration Overview15-03-99MCGN-44PKZ9
ServeRAID - Dead Channel Service Procedure15-03-99MCGN-44HS77
ServeRAID - Channel Troubleshooting Procedure15-03-99MCGN-44HSFN
ServeRAID II - Locations15-03-99MCGN-44LPQC
ServeRAID - PC ServeRAID Startup Messages15-03-99MCGN-44JKML
ServeRAID - Configuration Overview15-03-99MCGN-44HMRM
ServeRAID - Locations15-03-99MCGN-44JRJS
ServeRAID 3H - Configuration Overview15-03-99MCGN-44LS2P
Product Information
ServeRAID - Product Information11-02-99MCGN-44ZJCK
Service Hints & Tips
Cables
ServeRAID II - Missing DASD status cable11-02-99DDSE-42SUFN
Diagnostics
Netfinity 5500 - Diagnostics hangs when loading DOS ASPI24-02-99MCGN-3WPS9F
ECA
Servers - ECA031: Netfinity 10/100 Fault Tolerant Adapter fails reset17-05-99MIGR-47Z53E
PC Server 330 - ECA015: Firmware upgrade on some select models22-02-99MCGN-3QGKGD
Error Messages
Servers - Errors running ServeRAID 2.23 utility18-02-99MCGN-3NXN2F
PC Server 330 - Boot error after adding ServeRAID II adapter18-02-99DDSE-3QPNU2
Servers - ServeRAID adapter configuration error11-02-99COBN-3H3H86
PC Server 704 - Memory errors 801 and 0741 after installing ServeRAID adapter11-02-99DJON-3FAH3Y
Netfinity 3500 - 1801 PCI/PNP errors with 2 ServeRAID II11-02-99MCGN-3W8FQ7
Hard Drives
Servers - Using IBM RAID adapters to avoid data loss22-02-99MCGN-3N3MR4
PC Server 330 - Intermittent RAID problems (EMEA only)22-02-99MCGN-3P5MYA
PC Server 330 - Problem setting up EZ-RAID option (EMEA only)18-02-99MCGN-3NQP4X
Servers - Multiple DDD drives caused by incorrect channel mapping11-02-99MCGN-3XGFPW
Servers - ServeRAID rebuild issue with drive failures on multiple arrays11-02-99DDSE-3QQJ6Z
PC Server 330 - PC ServeRAID Adapter11-02-99GSMH-3E8FWF
Hardware Maintenance Information
PC Server 704 - Changing the ServeRAID Adapter Parameters22-02-99GKEY-3H9HFE
PC Server 704 - PC ServeRAID11-02-99GKEY-3H8AWN
PC Server 330 - Starting the ServeRAID Configuration Program11-02-99GSMH-3E8GGQ
PC Server 330 - Changing the ServeRAID Adapter Parameters11-02-99GSMH-3E8JFT
PC Server 704 - IBM PC ServeRAID administration and monitoring utilities11-02-99GCOR-3EGDUJ
PC Server 330 - Viewing the ServeRAID Configuration11-02-99GSMH-3E8GKR
PC Server 330 - Restoring the Disk-Array Configuration11-02-99GSMH-3E8J7Q
PC Server 330 - RAID Technology11-02-99GSMH-3E8G6D
PC Server 330 - Administration and Monitoring Utilities 11-02-99GSMH-3E8FZR
PC Server 330 - Additional Disk-Array Tasks11-02-99GSMH-3E8J5M
PC Server 330 - Performing Common Tasks11-02-99GSMH-3E8HCC
PC Server 330 - PC ServeRAID Adapter11-02-99GSMH-3E8FWF
PC Server 330 - ServeRAID Adapter Messages11-02-99GSMH-3E8JU3
Lock-up/Hang
Servers - ECA031: Netfinity 10/100 Fault Tolerant Adapter fails reset17-05-99MIGR-47Z53E
Netfinity 5500 - Diagnostics hangs when loading DOS ASPI24-02-99MCGN-3WPS9F
PC Server 330 - Boot error after adding ServeRAID II adapter18-02-99DDSE-3QPNU2
Microsoft Cluster Server
Servers - Failover of drive resources may fail in cluster environment24-02-99MCGN-3VAJVJ
NetWare
Netfinity 5500 - Unable to mount volumes in NetWare 4.11 with ServeRAID II and multiple SCSI adapters installed24-02-99MCGN-3V6GHZ
RAID
Netfinity 3000 - ServeRAID 3x are only supported in PCI slot 311-03-99MCGN-3YKNJ9
Servers - Failover of drive resources may fail in cluster environment24-02-99MCGN-3VAJVJ
Servers - Tips for increasing performance on the ServeRAID or ServeRAID II adapter24-02-99MCGN-3TAJX9
Servers - ServeRAID II adapter ships with hard drive flash diskette24-02-99MCGN-3QFTBQ
Servers - High availability using the IBM ServeRAID Adapter24-02-99MCGN-3N3KZG
Netfinity 5500 - Adaptec BIOS loading issue with greater than 7 logical drives24-02-99MCGN-3VHG7W
Netfinity 5500 - Unable to mount volumes in NetWare 4.11 with ServeRAID II and multiple SCSI adapters installed24-02-99MCGN-3V6GHZ
Netfinity 5500 - Diagnostics hangs when loading DOS ASPI24-02-99MCGN-3WPS9F
Servers - PC ServeRAID II and cable connections24-02-99MCGN-3NRTAC
Servers - RAID Array: Data scrubbing, prevent RAID rebuild failure22-02-99MCGN-3HKK6P
Servers - Security for the PC ServeRAID SCSI Adapter administration program22-02-99MCGN-3KMRTD
Servers - Using IBM RAID adapters to avoid data loss22-02-99MCGN-3N3MR4
PC Server 704 - Changing the ServeRAID Adapter Parameters22-02-99GKEY-3H9HFE
PC Server 330 - ECA015: Firmware upgrade on some select models22-02-99MCGN-3QGKGD
PC Server 330 - Problem setting up EZ-RAID option (EMEA only)18-02-99MCGN-3NQP4X
Servers - Errors running ServeRAID 2.23 utility18-02-99MCGN-3NXN2F
PC Server 330 - Boot error after adding ServeRAID II adapter18-02-99DDSE-3QPNU2
PC Server 704 - PC ServeRAID11-02-99GKEY-3H8AWN
Netfinity 7000 - ServeRAID and ServeRAID II11-02-99MCGN-3NCPSR
Servers - Netfinity servers cannot create the file A:\raidevt.log11-02-99MCGN-3YKN7W
PC Server 330 - Starting the ServeRAID Configuration Program11-02-99GSMH-3E8GGQ
Servers - ServeRAID adapter configuration error11-02-99COBN-3H3H86
PC Server 330 - Changing the ServeRAID Adapter Parameters11-02-99GSMH-3E8JFT
PC Server 704 - Memory errors 801 and 0741 after installing ServeRAID adapter11-02-99DJON-3FAH3Y
PC Server 704 - IBM PC ServeRAID administration and monitoring utilities11-02-99GCOR-3EGDUJ
PC Server 330 - Viewing the ServeRAID Configuration11-02-99GSMH-3E8GKR
Servers - Multiple DDD drives caused by incorrect channel mapping11-02-99MCGN-3XGFPW
Netfinity 3500 - 1801 PCI/PNP errors with 2 ServeRAID II11-02-99MCGN-3W8FQ7
PC Server 330 / Netfinity 5500 - Drives may not automatically rebuild in RAID environment11-02-99MCGN-3YVFV7
Servers - ServeRAID adapter hints and tips11-02-99SRUL-3DZKCK
Servers - Intermittent False DDDs in a 3518 Disk Enclosure11-02-99MCGN-3QGQU9
PC Server 330 - Restoring the Disk-Array Configuration11-02-99GSMH-3E8J7Q
PC Server 330 - RAID Technology11-02-99GSMH-3E8G6D
Servers - Correct concurrent drive spin-up on power-up settings11-02-99MCGN-3XGQUP
PC Server 330 - Administration and Monitoring Utilities 11-02-99GSMH-3E8FZR
PC Server 330 - Additional Disk-Array Tasks11-02-99GSMH-3E8J5M
Servers - ServeRAID rebuild issue with drive failures on multiple arrays11-02-99DDSE-3QQJ6Z
PC Server 330 - Performing Common Tasks11-02-99GSMH-3E8HCC
ServeRAID II - Missing DASD status cable11-02-99DDSE-42SUFN
PC Server 330 - ServeRAID Adapter Messages11-02-99GSMH-3E8JU3
Servers - Performance enhancements for ServeRAID I and II adapters11-02-99MCGN-3UFGYQ
Retain
Servers - ECA031: Netfinity 10/100 Fault Tolerant Adapter fails reset17-05-99MIGR-47Z53E
Netfinity 3000 - ServeRAID 3x are only supported in PCI slot 311-03-99MCGN-3YKNJ9
Servers - Failover of drive resources may fail in cluster environment24-02-99MCGN-3VAJVJ
Netfinity 5500 - Adaptec BIOS loading issue with greater than 7 logical drives24-02-99MCGN-3VHG7W
Netfinity 5500 - Diagnostics hangs when loading DOS ASPI24-02-99MCGN-3WPS9F
Servers - RAID Array: Data scrubbing, prevent RAID rebuild failure22-02-99MCGN-3HKK6P
PC Server 330 - Intermittent RAID problems (EMEA only)22-02-99MCGN-3P5MYA
PC Server 330 - Problem setting up EZ-RAID option (EMEA only)18-02-99MCGN-3NQP4X
Servers - Errors running ServeRAID 2.23 utility18-02-99MCGN-3NXN2F
PC Server 330 - Boot error after adding ServeRAID II adapter18-02-99DDSE-3QPNU2
Servers - Netfinity servers cannot create the file A:\raidevt.log11-02-99MCGN-3YKN7W
Servers - ServeRAID adapter configuration error11-02-99COBN-3H3H86
Servers - Multiple DDD drives caused by incorrect channel mapping11-02-99MCGN-3XGFPW
Netfinity 3500 - 1801 PCI/PNP errors with 2 ServeRAID II11-02-99MCGN-3W8FQ7
PC Server 330 / Netfinity 5500 - Drives may not automatically rebuild in RAID environment11-02-99MCGN-3YVFV7
Servers - Correct concurrent drive spin-up on power-up settings11-02-99MCGN-3XGQUP
Servers - Performance enhancements for ServeRAID I and II adapters11-02-99MCGN-3UFGYQ
SCSI
Netfinity 5500 - Unable to mount volumes in NetWare 4.11 with ServeRAID II and multiple SCSI adapters installed24-02-99MCGN-3V6GHZ
ServerGuide
ServerGuide - Update packages29-03-99DDSE-45ZQ4Z
Tape Drives
Tape Drives - Questions and Answers07-04-99VLAR-3X9NYC
Service Publications
ServeRAID 3H - IBM Netfinity High Availability Cluster Solutions using the IBM ServeRAID-3H Ultra2 SCSI Adapter Installation and User's Guide, Fourth Edition14-04-99SCOD-43UKZ3
Netfinity 5500 M10 / 5500 M20 - ServeRAID Information18-03-99SCOD-3XQH3D
ServeRAID - Hardware Maintenance Manual18-02-99MCGN-424RDV
ServeRAID-3H / 3L - Installation and User's Guide18-02-99MCGN-3YFM7R
ServeRAID / ServeRAID II - UltraSCSI Adapter Installation Instructions and User's Guide18-02-99DDSE-3SURN3
ServeRAID-3H / 3L - IBM Netfinity Update to the ServeRAID-3H and ServeRAID-3L Ultra2 SCSI Adapters Installation and User's Guide11-02-99SCOD-43DRCL
System Support Disks
RAID
ServeRAID - Diskettes v3.10J (Japanese)27-05-99YAST-3V6NVF
ServeRAID - Diskettes version 3.10 & 3.11B14-04-99MQUN-3V2RSD
Netfinity 3000 - ServeRAID Diskettes v3.10 & 3.11B24-03-99SCOD-45CJKF