Subject: PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT
New Netfinity server RETAIN Tip:
Record number: H167938
Device: D/T8664
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key: 002
Date created: O99/12/15
Date last altered: A99/12/23
Owning B.U.: USA
Abstract: PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT
TEXT:
PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT
SYMPTOM:
If the PCI hot swap latch and PCI hot swap LED diagnostic tests are run with adapters present
in the hot swap slots, the adapters may not be responsive when power is returned to the adapter.
PROBLEM ISOLATION AIDS:
a Netfinity 5600 server, Type 8664, any Model.
Note: (build level can be seen in Setup under Product Information)
FIX:
1st quarter 2000
http://www.pc.ibm.com/searchfiles.html
search on "Netfinity 5600 diagnostic"
WORKAROUND:
Don't run the hot swap latch test or the hot swap LED test with diagnostic version
TNYx22A or below if the slot is populated.
Note: The diagnostic level can be viewed in F1 Setup under Product Information.
DETAILS:
These tests remove power to the slot and when power is returned the adapter is not initialized.
A new level of Diagnostic will be available 1st Quarter 2000 which will not allow populated slots
to be selected during the PCI hot swap latch and LED tests.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.