PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT


Subject: PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT
New Netfinity server RETAIN Tip: 

    Record number:       H167938
    Device:              D/T8664
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:             002
    Date created:        O99/12/15
    Date last altered:   A99/12/23
    Owning B.U.:         USA


Abstract: PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT


TEXT:

PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT


SYMPTOM:

If the PCI hot swap latch and PCI hot swap LED diagnostic tests are run with adapters present in the hot swap slots, the adapters may not be responsive when power is returned to the adapter.


PROBLEM ISOLATION AIDS:


FIX:


WORKAROUND:

Don't run the hot swap latch test or the hot swap LED test with diagnostic version TNYx22A or below if the slot is populated.

Note: The diagnostic level can be viewed in F1 Setup under Product Information.


DETAILS:

These tests remove power to the slot and when power is returned the adapter is not initialized.

A new level of Diagnostic will be available 1st Quarter 2000 which will not allow populated slots to be selected during the PCI hot swap latch and LED tests.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.