SERVERAID: BATTERY BACKUP WRITE CACHE ERROR


Subject: SERVERAID: BATTERY BACKUP WRITE CACHE ERROR
New Netfinity server RETAIN Tip: 

    Record number:       H201087
    Device:              D/T8681
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/12/19
    Date last altered:   A99/12/20
    Owning B.U.:         USA


Abstract: SERVERAID: BATTERY BACKUP WRITE CACHE ERROR


SYMPTOM:

The following error message appears after powering on the system:

"Battery Backup Write Cache was defective at last power-on"


PROBLEM ISOLATION AIDS:


FIX:

Apply ServeRAID firmware Release 3.60 or later.

Download and apply the "IBM ServeRAID Diskette version 3.60" from the following URL:

ftp://ftp.pc.ibm.com/pub/pccbbs/pc_servers/09n8244.exe


WORKAROUND:

Press F8 battery Backup Write Cache has been replaced.


DETAILS:

There is a potential for a false error message to be reported by the ServeRAID adapter during ServeRAID post.
This false message was corrected in ServeRAID firmware version 3.60.

If after applying 3.60 the problem persists, replace the Battery Backup Cache, FRU P/N 09L2105.