Subject: LARGE RAID LOGICAL DRIVE FAILS UNDER UNIXWARE 7.1
New Netfinity server RETAIN Tip:
Record number: H20340
Device: D/T8681
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key: 006
Date created: O99/12/07
Date last altered: A99/12/07
Owning B.U.: USA
Abstract: LARGE RAID LOGICAL DRIVE FAILS UNDER UNIXWARE 7.1
TEXT:
Large RAID logical drive fails under UnixWare 7.1
SYMPTOMS:
UnixWare 7.1 will not install onto a logical drive that is greater than 128GB.
Attempting to install onto a logical drive that is greater than 128GB results
in errors with "Unable to find root drive".
Anything under 128GB logical drive size is not affected.
PROBLEM ISOLATION AIDS:
a Netfinity 8500R server, Type 8681, any Model.
a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 5500-M20 server, Type 8662, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 3500-M10 server, Type 8655, any Model.
a Netfinity 3000 server, Type 8476, any Model.
a Netfinity 1000 server, Type 8477, any Model.
WORKAROUND:
The recommended and guaranteed solution is to use the existing
ISL (Initial System Load) infrastructure to modify the filesystem block size to at least 2048 bytes.
This is easily achieved during the installation by the following procedure:
TRADEMARKS:
Other company, product and service names may be the trademarks or service marks of others.