Subject: COMMAND TIMEOUTS LOGGED IN WINDOWS NT WITH 7200 RPM 36GB HDD
New Netfinity server RETAIN Tip:
Record number: H167816
Device: D/T8681
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/11/17
Date last altered: A99/11/18
Owning B.U.: USA
Abstract: COMMAND TIMEOUTS LOGGED IN WINDOWS NT WITH 7200 RPM 36GB HDD
SYMPTOM:
Command Timeouts logged in Windows NT as event 9's with 7200 RPM 36GB Hard Drive.
PROBLEM ISOLATION AIDS:
a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 5500-M20 server, Type 8662, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
NETFINITY EXP 36.4GB WIDE ULTRA SCSI HOT-SWAP HDD,
Option P/N 02K0441, FRU P/N 08L8428.
FIX:
Apply IBM Hard Drive Update Program version 1.02 or later.
The four (4) image files are available from the following URL:
http://www.pc.ibm.com/searchfiles.html
search on "Hard Drive Update Program Diskette"
To create an update diskette; the downloaded files
(e.g. 09n7709.exe, 09n7710.exe, 09n7711.exe and 09n7712.exe)
are self-extracting executable files that will prompt for a diskette.
Follow instructions on the display to create the diskette.
DETAILS:
This behavior is corrected in Firmware 0272.
You can determine your firmware as follows:
This should read 'DRHS36D 0272.'
This should read 0272
This should read 0272
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.