CI SLOT DOES NOT POWER ON DURING HOT ADD


Subject: PCI SLOT DOES NOT POWER ON DURING HOT ADD
Updated Netfinity server RETAIN Tip: 

    Record number:       H131159
    Device:              D/T8681
    Model:               M
    Hit count:           UHC00020
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/09/28
    Date last altered:   A99/11/30
    Owning B.U.:         USA


Abstract: PCI SLOT DOES NOT POWER ON DURING HOT ADD


SYMPTOM:

If while you are adding a Hot-Plug PCI card, the locating tab mechanism is flicked up and down, the PCI card will power on, then off and then may not power back up.
This will be indicated by the green Hot-Plug power status LED not illuminating when the card is inserted and latched in place.


PROBLEM ISOLATION AIDS:


FIX:

It is recommended that the hot-plug PCI latch mechanism be folded down onto the PCI I/O bracket and held down while the orange locating flag is rotated to hold the PCI card in place.
This will prevent the latch from moving back into the open position and switching off power to the card.
If the green Hot-Plug power status LED does not illuminate when the PCI card has been added and fixed in place with the latch mechanism, remove the card, fold down the latch on the empty slot to reset the slot state to empty, lift the latch, and reinsert following the procedure above.