EXP 15: BAD DATA AFTER INITIAL DATA INQUIRY OF SCSI ADAPTER


Subject: EXP 15: INCORRECT RETURN FROM INQUIRY COMMAND
Updated Netfinity server RETAIN Tip: 

    Record number:       H167384
    Device:              D/T3520
    Model:               M
    Hit count:           UHC00003
    Success count:       USC0000
    Publication code:    PC50
    Tip key:             001
    Date created:        O99/09/30
    Date last altered:   A99/10/07
    Owning B.U.:         USA



Abstract: EXP 15: INCORRECT RETURN FROM INQUIRY COMMAND


TEXT:

After initial data inquiry of SCSI adapter on EXP 15 an incorrect return from inquiry command occurs.


SYMPTOMS:

After the EXP 15 retrieves inquiry data the first time from the SCSI adapter, all future requests will result in an incorrect return; it will look something like the following at the expansion unit's SCSI address:

       Device ID:    ˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜˜2   ˜˜˜


Note: This does not cause problems with the running of the machine.


PROBLEM ISOLATION AIDS:


WORKAROUND:

Power off the EXP 15 and power it back on.

When it first comes back up, it will give good data.
On each subsequent inquiry, the Data will come out as above.

Note: This does not impact the running of the EXP 15 at all.