NETFINITY 5500: DIAGNOSTICS REPORT FAILURE WITH SERVERAID


Subject: NETFINITY 5500: DIAGNOSTICS REPORT FAILURE WITH SERVERAID
New Netfinity server RETAIN Tip: 

    Record number:       H167346
    Device:              D/T8660
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/09/20
    Date last altered:   A99/09/29
    Owning B.U.:         USA


Abstract: NETFINITY 5500: DIAGNOSTICS REPORT FAILURE WITH SERVERAID


SYMPTOM:

When the system's diagnostics are used to test the on-board ServeRAID, ServeRAID II or Netfinity ServeRAID 3X adapter, the following message appears in the test log:

       "Failure (Config status: basic config status=9, extended
        config status=0 032-253-000-YYYYMMDD-32-RAID Interface:
        RAID Adapter Initialization Failure). Could not
        initialize ServeRAID adapter on bus X in slot X."


PROBLEM ISOLATION AIDS:


FIX:

Download and install IBM Netfinity 5500, 5500-M10 and 5500-M20 Diagnostic Update, version 3.02 or higher.

The file is available from the following URL:

http://www.pc.ibm.com/searchfiles.html
search on "Netfinity 5500 Diagnostic"

Note: Removal of adapters is no longer necessary when running diagnostics if version 3.02 is used.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.