Subject: SERVER INSTABILITY, HANGS, UNABLE TO INSTALL NOS
New Netfinity server RETAIN Tip:
Record number: H167340
Device: D/T8680
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/05/14
Date last altered: A99/09/28
Owning B.U.: USA
Abstract: SERVER INSTABILITY, HANGS, UNABLE TO INSTALL NOS
SYMPTOM:
Symptoms include but not limited to the following:
PROBLEM ISOLATION AIDS:
a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 5500-M20 server, Type 8662, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 3500 server, Type 8644, any Model.
a Netfinity 3000 server, Type 8476, any Model.
a PC Server 720, Type 8642, any Model.
a PC Server 704, Type 8650, any Model.
a PC Server 520, Type 8641, any Model.
a PC Server 330, Type 8640, any Model.
a PC Server 325, Type 8639, any Model.
a PC Server 320, Type 8640, any Model.
a PC Server 315, Type 8638, any Model.
Onboard ServeRAID
a PC ServeRAID SCSI Adapter, Option P/N 70G8489
a ServeRAID II Ultra SCSI Adapter, Option P/N 76H3584
a Netfinity ServeRAID-3H Ultra2 SCSI Adapter,
Option P/N 01K7207
a Netfinity ServeRAID-3L Ultra2 SCSI Adapter,
Option P/N 01K7364
FIX:
Apply the following updates:
WORKAROUND:
This problem is only seen when the Autosynch is running on a RAID-5 Logical Drive
with 10 or more physical drives.
The workaround is to wait until the Autosynch is finished before proceeding.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.