Subject: NETFINITY 7000-M10: SYSTEM MAY EXHIBIT CP66 HANG
New Netfinity server RETAIN Tip:
Record number: H022938
Device: D/T8680
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/09/03
Date last altered: A99/09/03
Owning B.U.: USA
Abstract: NETFINITY 7000-M10: SYSTEM MAY EXHIBIT CP66 HANG
SYMPTOM:
System may exhibit a CP66 hang on a cold boot due to an Intel CPU errata.
PROBLEM ISOLATION AIDS:
31A / Version 4 (1.03)
FIX:
The fix is to flash the system to BIOS level 33A / Version 5 (1.04) or later.
Note: This will require installing another CPU in the boot slot so system will start.
After flashing, any CPU will run correctly.
BIOS image files (e.g. 00n9076.exe) are available from the following URL:
http://www.pc.ibm.com/searchfiles.html
search on "Netfinity 7000 M10 BIOS" download 1.04 or later
The corresponding Text file (e.g. 00n9076.txt) is viewable on-line and may be printed.
To create a BIOS update diskette; the downloaded file (e.g. 00n9076.exe) is a self-extracting executable
file that will prompt for a diskette.
Follow instructions on the display to create the diskette.
WORKAROUND:
The system will also boot if a new processor is installed in the boot processor slot.
If this is done, the system should be flashed to BIOS 33A upon starting to prevent future fails for CP66.
DETAILS:
CP66 occurs due to an errata fix in the Intel CPUs for CP37 problem.
In the previous BIOS CP37 was fixed but the patch caused an early start of errata in the CPU and this caused CP66.
TRADEMARKS:
Other company, product and service names may be the trademarks or service marks of others.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.