FAILOVER ISSUES: SSA CLUSTER ADAPTER AND HOST SW 1.06, 1.07


Subject: FAILOVER ISSUES: SSA CLUSTER ADAPTER AND HOST SW 1.06, 1.07
Updated Netfinity server RETAIN Tip: 

    Record number:       H166375
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/04/28
    Date last altered:   A99/04/28
    Owning B.U.:         USA


Abstract: FAILOVER ISSUES: SSA CLUSTER ADAPTER AND HOST SW 1.06, 1.07


SYMPTOM:

Microsoft Cluster Server (MSCS) Failover will hang and will not complete.


PROBLEM ISOLATION AIDS:


FIX:

Fix will be implemented in a future revision of the driver and adapter firmware.


WORKAROUND:

Use Windows NT SP 3 and the 1.05 driver package, which ships with the SSA RAID Cluster Adapter.

The 1.05 package is also available at:

http://www.hursley.ibm.com/~ssa/pcserver

Note: There is no workaround with NT SP4 until the new driver and firmware is released.


DETAILS:

An issue with SSA driver package versions 1.06 and 1.07 causes problems when used with Microsoft Cluster Server.
In this environment, MSCS failover will hang and will not complete.

Operation in a non-clustered (one-way) environment is unaffected.
Because SP4 is required for the SerialRAID Adapter (Option 09L2084/7133 Feature Code 4013) and Advanced SerialRAID/X Adapter (Option 09L2123 / 7133 Feature Code 4040), use of the SSA RAID Cluster Adapter in the same system as either the SerialRAID Adapter or Advanced SerialRAID/X Adapter is unsupported when used in conjunction with Microsoft Cluster Server.


TRADEMARKS:

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or other countries.

Other company, product and service names may be the trademarks or service marks of others.