MULTI-SERVERAID: MISCELLANEOUS EVENTS OCCUR IN THE EVENT LOG


Subject: MULTI-SERVERAID: MISCELLANEOUS EVENTS OCCUR IN THE EVENT LOG
New Netfinity server RETAIN Tip: 

    Record number:       H166172
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/03/25
    Date last altered:   A99/03/29
    Owning B.U.:         USA


Abstract: MULTI-SERVERAID: MISCELLANEOUS EVENTS OCCUR IN THE EVENT LOG


SYMPTOM:

Large number of soft and miscellaneous events occur in the ServeRAID soft event log and device event table.


PROBLEM ISOLATION AIDS:

       a Netfinity 7000-M10 server, Type 8680, any Model.
       a Netfinity 7000 server, Type 8651, any Model.
       a Netfinity 5500-M20 server, Type 8662, any Model.
       a Netfinity 5500-M10 server, Type 8661, any Model.
       a Netfinity 5500 server, Type 8660, any Model.
       a Netfinity 5000 server, Type 8659, any Model.
       a Netfinity 3500 server, Type 8644, any Model.
       a Netfinity 3000 server, Type 8476, any Model.
       a Netfinity 704 server, Type 8650, any Model.
       a PC Server 720, Type 8642, any Model.
       a PC Server 520, Type 8641, any Model.
       a PC Server 330, Type 8640, any Model.
       a PC Server 325, Type 8639, any Model.
       a PC Server 320, Type 8640, any Model.
       a PC Server 315, Type 8638, any Model.
       a PC Server 310, Type 8639, any Model.


Note: The Netfinity ServerProven Compatibility web page is at the following URL:

http://www.pc.ibm.com/us/compat/

      ServeRAID Adapter FRU P/N 06H9334 (Option P/N 70G8489)
      ServeRAID Adapter FRU P/N 76H6875 (Option P/N 70G8489)
      ServeRAID II Adapter FRU P/N 76H3587 (Option P/N 76H3584)
      ServeRAID-3H Adapter FRU P/N 01K7396 (Option P/N 01K7207)
      ServeRAID-3L Adapter FRU P/N 01K7352 (Option P/N 01K7364)



Novell NetWare version 4.2 w/ IWSP6 applied.


FIX:



http://www.pc.ibm.com/searchfiles.html
search on "ServeRAID Firmware"


WORKAROUND:


DETAILS:

This problem may occur when the system's cache is highly utilized, a logical drive is in critical state (1 DDD drive) and 2 types of ServeRAID Adapters are installed.
This problem has only been able to be replicated in development test when a drive goes DDD during an "add to free array space" LDM operation in NetWare v4.2 with IWSP6, a large amount of network activity, and two types of ServeRAID adapters installed in the system.

Note: It may occur with other operating systems if the conditions regarding highly utilized cache with a critical logical drive are met, but development has not been able to replicate in any other operating system environment besides NetWare.


TRADEMARKS:

Other company, product and service names may be the trademarks or service marks of others.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.