FALSE ERROR MESSAGE when RESTARTING SERVICE PROCESSOR


Subject: FALSE ERROR MESSAGE when RESTARTING SERVICE PROCESSOR
Updated Netfinity server RETAIN Tip: 

    Record number:       H001448
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00004
    Success count:       USC0000
    Publication code:    PC50
    Tip key:             010
    Date created:        O99/01/04
    Date last altered:   A99/01/05
    Owning B.U.:         USA


Abstract: FALSE ERROR MESSAGE when RESTARTING SERVICE PROCESSOR


TEXT:

False error message when restarting service processor.


SYMPTOMS:

When a user presses the Restart button under the Network Settings window in the Configuration Settings window in the Advanced System Management service in Netfinity Manager to restart the service processor, sometimes an error message box will pop-up that says there was a command time-out. It occurs much more frequently in OS/2 than Windows NT.


PROBLEM ISOLATION AIDS:


WORKAROUND:

Go into the Network Driver Configuration program which comes with Netfinity Manager and change the Network Time-Out from 15 to 30 seconds.


DETAILS:

Rarely occurs under Windows NT, changing time-out value gives service processor more time to respond, the restarting actually succeeds so it is a false error message.


TRADEMARKS:

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or other countries.


Back to  Jump to TOP-of-PAGE