INCORRECT POWER SUPPLY STATUS, after ADDING a POWER SUPPLY


Subject: INCORRECT POWER SUPPLY STATUS, after ADDING a POWER SUPPLY
New Netfinity server RETAIN Tip: 

    Record number:       H165135
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:             007
    Date created:        O98/11/02
    Date last altered:   A98/11/02
    Owning B.U.:         USA


Abstract: INCORRECT POWER SUPPLY STATUS, after ADDING a POWER SUPPLY


TEXT:

Adding an extra power supply to Netfinity 7000 M10 causes the Service Processor to issue an incorrect power supply status.
Recovery message is logged in the event log. This confirms that power supply is operating correctly.


SYMPTOM:

Upon hot-adding a power supply, the error log will log a power supply failure in that particular slot together with power supply recovery messages.
Following is the sequence of error messages:

       Power Supply x Fault
       Power Supply x DC Good Fault
       Recovery Power Supply x Fault
       Recovery Power Supply x DC Good Fault


PROBLEM ISOLATION AIDS:


WORKAROUND:

Disregard the power supply failure error messages since they are not valid statements.

DETAILS:

These errors will not be generated if the additional power supply is added prior to system power-up.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.