SSA RAID ADAPTER RESTRICTED to RAID 5 with OVER 2GB OF RAM


Subject: SSA RAID ADAPTER RESTRICTED to RAID 5 with OVER 2GB OF RAM
New Netfinity server RETAIN Tip: 

    Record number:       H165049
    Device:              D/T8651
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/10/13
    Date last altered:   A98/10/28
    Owning B.U.:         USA


Abstract: SSA RAID ADAPTER RESTRICTED to RAID 5 WITH OVER 2GB OF RAM


SYMPTOM:

System crash (including NT bluescreen or NetWare abend), system hang, garbled video, other unpredictable results.


PROBLEM ISOLATION AIDS:


FIX:

This restriction will be removed in a future SSA RAID adapter.


WORKAROUND:


DETAILS:

A 2 GB memory limit shall be observed on all servers with the IBM SSA RAID Adapter for PC Servers (except RAID 5 use) or IBM SSA RAID Cluster Adapter installed.
On server systems with greater than 2 GB of memory installed, the use of either:

  1.  JBOD (single disks), RAID 0, or RAID 1 on the SSA RAID Adapter for PC Servers,

      -- or --

  2.  JBOD or RAID 1 on the SSA RAID Cluster Adapter will cause unpredictable results and is not supported by IBM.


TRADEMARKS:

Other company, product and service names may be the trademarks or service marks of others.

Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or other countries.