Subject: ETHERNET DIAGNOSTICS FAILS if an EXTERNAL WRAP is ATTACHED
New Netfinity server RETAIN Tip: 
    Record number:       H164897
    Device:              D/T8660
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/10/08
    Date last altered:   A98/10/13
    Owning B.U.:         USA
Abstract: ETHERNET DIAGNOSTICS FAILS if an EXTERNAL WRAP is ATTACHED
SYMPTOM:
The following Ethernet tests will erroneously report a failure
when they are run with an external wrap plug attached to the Ethernet port:
       Ethernet Int 10  MBS Phy Wrap
       Ethernet Int 100 MBS Phy Wrap
       Ethernet Int 100 MBS Twist Wrap
PROBLEM ISOLATION AIDS:
FIX:
With diagnostic version 2.01 these tests will not report
erroneous failures with or without an external wrap plug attached to the Ethernet port.
WORKAROUND:
Run the test mentioned without an external wrap plug installed.