ECA020: POWER TERMINATOR for BACKPLANES in 3518 ENCLOSURE


Subject: ECA020: POWER TERMINATOR for BACKPLANES in 3518 ENCLOSURE
Updated PC Server RETAIN ECA020: 


This ECA is now "Mandatory".

    Record number:       H164971
    Device:              D/T3518         Service code:      33
    ECA number:          ECA020          Parts source:      LOC
    EC number:           EC000000        Publish flag:      R
    Mandatory:           Y               Hit count:         UHC00009
    Automatic shipment:  N               Success count:     USC0000
    Availability date:   98/05           Publication code:  PC50
    Plant of control:    23              Date created:      O98/05/18
    Tip key:                             Date last altered: A98/10/23
                                         Owning B.U.:       USA

Abstract: ECA020: POWER TERMINATOR for BACKPLANES in 3518 ENCLOSURE


PURPOSE:

This ECA provides for the installation of a Power Termination Plug on backplanes in a IBM PC Server Enterprise Expansion Enclosure.

This ECA is applicable if the configuration of the 3518 holds true to the "Physical Check" section of this document.

This ECA will expire December 30, 2004


FEATURES:

  Type,                  Machines Affected
  Model,   With          and/or Feature/Device     B/M to be    Service  System
  Stage    B/M           Description               Installed    Hours    Hours
                         USA:
  3518     B/M0000000    TYPE 3518 ALL MODELS      B/M0000000   00.8     00.3
                         EMEA:
                         TYPE 3518 ALL MODELS
                         TRAVEL PER SITE: 0.8HR
                         SERVICE PER
                         SYSTEM:          0.8HR


PHYSICAL CHECK:

All of the following must be true for this ECA to apply:


PREREQUISITES: NONE


COMPANION:

None


CONCURRENT:

None


DETAIL:

Install a SCSI Power Terminator FRU P/N 03K9283 on the exit cable connector on the Hot-Swap backplane(s) that has ONLY one attached SCSI Cable.

  1.  Power OFF the 3518 Enclosure and the Attached Server.
  2.  Open the front Cover faceplate of the 3518 enclosure.
  3.  Locate the black latch on the left side and lift it  from the bottom. Pull the entire front cover off starting  working from the top to the bottom.
  4.  Open the side access panel door.
  5.  Remove the two screws (shown by stars below). This will  release the front half of the fan assembly.
     Lift the entire fan assembly approximately 1/2 inch to release  from slots on the backside.

                    _____________
                   |  | |        |
                   | *|_|        |
                   |  | |        |
             Front |  | |        |
                   | *|_|        |
                   |  |          |
                   |__|    ______|
                    ______|______|
     

  6.  Carefully rotate the fan assembly towards the back of the  enclosure, taking care to avoid stressing the fan power cables.
  7.  Locate the exit cable connector at the far end of the  backplane (opposite end from jumpers) as depicted below.

                           Hot-Swap backplane
          _______________________________________________________
         |          <...><....>                 ::   <...>       |
         | """" |\                                           |\  |
         | ::   |||                                          ||| |
         |  '   |||                                          ||| |
         | :::: |||<--SCSI Cable here     Power Term. here-->||| |
         |      |||                              (exit conn.)||| |
         |      |||    ___                                   ||| |
         |      |||   |   |                                  ||| |
         |      |/    |___|  <....>          <....>       J13|/  |
         |_______________________________________________________|
     

  8.  Insert the Power Terminator FRU p/n03K9283 into the exit connector.  Push it firmly but gently.
  9.  Reinstall the fan assembly making certain to seat the back side properly into the slots.
  10.  Secure the front side of the fan assembly with the original 2 screws.
  11.  Close the side door.
  12.  Reinstall the front cover being sure to secure the black latch on the left side.
  13.  Power up the 3518 Enclosure.
  14.  Power up the Server.

NOTEs:

This ECA is "Mandatory"

This ECA will expire December 30, 2004


USA:

IBM TSS CE's should record all time and parts to Service code 33, ECA020, Other Office 990.
FRU P/N 03K9283 should be ordered code B.


EMEA:

IBM PSS CE's should record all time and parts to Service code 33, (3518) ECA020, Other Office 990.
FRU P/N 03K9283 should be ordered code B.

Business Partners Claims: Refer to Warranty Claim System, Use Emergency Claim 5 (ECA) and Quote ECA No. and M/T 3518.

Order P/N 03K9283 for parts required.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.