NETFINITY 7000: DLT Tape option CLEANING Light Remains On


Subject: NETFINITY 7000: DLT TAPE OPTION CLEANING LIGHT REMAINS ON
New PC Server RETAIN TIP: 

     Record number:       H163783
     Device:              D/T8651
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:
     Date created:        O98/05/26
     Date last altered:   A98/05/27
     Owning B.U.:         USA


Abstract: NETFINITY 7000: DLT TAPE OPTION CLEANING LIGHT REMAINS ON

SYMPTOM:

The cleaning light (amber color LED located on the right column of LED's) on the IBM 35/70GB Internal DLT Tape Drive remains on.


PROBLEM ISOLATION AIDS:

All of the following must be true for this TIP to apply:


FIX:

  1.  Remove any cable (captured by the white cable clamp located  at the right rear of bay #3) from the cable clamp.
  2.  Remove the cable clamp.


DETAIL:

When the "IBM 35/70GB Internal Tape Drive" is located in bays 3 and 4 of the System, a white cable clamp, if installed, can press against the housing of the Tape Drive causing a false activation of the cleaning light.
Removing the cable clamp resolves this issue.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.