NETFINITY 3500: System HANGs/No VIDEO after 333MHZ Upgrade


Subject: NETFINITY 3500: SYSTEM HANGS/NO VIDEO AFTER 333MHZ UPGRADE
New Netfinity server RETAIN TIP: 

     Record number:       H012700
     Device:              D/T8644
     Model:               M
     Hit count:           UHC00000
     Success count:       USC0000
     Publication code:    PC50
     Tip key:
     Date created:        O98/04/29
     Date last altered:   A98/05/08
     Owning B.U.:         USA


See also ECA019

Abstract: NETFINITY 3500: SYSTEM HANGS/NO VIDEO AFTER 333MHZ UPGRADE

SYMPTOM:

The System hangs with no video displayed after a warm or cold boot.

PROBLEM ISOLATION AIDS:

All of the following must be true for this TIP to apply:



NOTE: If the System is configured with one 333MHz Proccessor, the Processor Bus terminator card must be in the second Processor Slot. If the System is configured with two Processors, both Processors must be the same speed (MHz).


FIX:

Contact the IBM PSGHC (Personal Systems Group Help Center) at 1-800-772-2227 for assistance.


Workaround:

Re-install the 233MHz or 266MHz Processor(s) to recover System functions.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.