- Flash BIOS / SERVER (HINTs - TIPs)
Available BIOS (FLASH) Diskette Versions
SERVER's (HINTs - TIPs)
- 1998 -
- 98/01/14 - H162521 NETFINITY 7000 - Diagnostics selects ONLY on ONE Hard Drive
- 98/01/15 - H162440 Lost HW-INTERRUPTS Running NOVELL NetWare 3.12
- 98/03/11 - H163238 Server 325/330 Some Serial Port resource Setting Fail
- 98/03/17 - H163045 NETFINITY 7000 - Cooling FAILURE LIGHT blinks slowly
- 98/03/24 - H123817 NETWARE 3X / 4X WILL NOT AUTO REGISTER >16MB OR >64MB RAM
- 98/03/25 - H007138 PC SERVER 325/330 LOST HARDWARE INTERRUPT with NETWARE 3X/4X
- 98/03/25 - H162710 KEYBOARD LOCK-UP with BIOS 42A on PC SERVER 325/330
- 98/03/31 - H163222 Clients report INVALID INFO to "CAPACITY MANAGEMENT" queries
- 98/04/08 - H163301 GPPE, PAGE FAULT ABEND RUNNING NETWARE 3X/4X (SPXS Patch)
- 98/04/10 - H163080 NETFINITY 3500 - SCO OpenServer INSTALL REQUIRES BIOS Flash
- 98/04/13 - H163355 SERVERGUIDE 4.01: SOFTWAREGUIDE CD HANGS IN PC SERVER 325
- 98/04/20 - H163372 PC Server 330 hangs during NETWORK OPSYS installation
- 98/04/20 - H163424 Configuring MEMORY Resources for A.S.M.A.
- 98/04/20 - H163426 8644 Hardfile Installation
- 98/04/28 - H163496 PC DOCTOR diagnostics skips / hangs testing with TAPE drive
- 98/04/29 - H163507 INTRANETWARE fails install w/ 7870 driver on 7895 controller
- 98/05/08 - H012700 System HANGs/No VIDEO after 333MHZ Upgrade Netfinity 3500-8644
- 98/05/18 - H173727 PC SERVER 325: A.S.M.A. LOGS / REPORTS false FAN Failures
- 98/05/20 - H163746 A.S.M.A. DIAL-OUT Function may NOT COMMUNICATE ALERT
- 98/05/27 - H163783 NETFINITY 7000: DLT Tape option CLEANING Light Remains On
- 98/06/02 - H037848 PC Server 720 Health Checklist
- 98/06/02 - H163830 NETFINITY 5500: VIDEO Adapters NOT Supported by sec. PCI Bus
- 98/06/04 - H163827 A.S.M.A.: Critical Event DIALOUT CODES / DATA
- 98/06/08 - H127428 ERRONEOUS ECC errors detected by NETFINITY manager 5.1
- 98/06/10 - H163847 NETFINITY 5500: BOOT MGR. appears HUNG with REMOTE CONNECT
- 98/06/11 - H163901 NETFINITY 3500: POWER SUPPLY may LATCH-OFF running 230VAC
- 98/06/16 - H123132 RESOURCE CONFLICTS with shared INTERRUPTS running NETWARE
- 98/06/17 - H136842 SERVER 720 HANGS at CP 69 after PLANAR Replacement
- 98/06/25 - H164035 Netfinity 3000/3500 POWER-ON Switch PROTECTOR (Cover)
- 98/06/25 - H164201 SERVERGUIDE: HARDWAREGUIDE HANGS SERVER when > 1GB RAM
- 98/07/02 - H164076 SYSTEM HANGs with NT 4.0 SP3 in SMP MODE and TCP/IP
- 98/07/06 - H13313 PC Server 704/330/325/315 may TRAP, HANG, or REBOOT
- 98/07/07 - H126380 PC SERVER 330: MALFUNCTIONS w/ full length ADAPTER in SLOT 6
- 98/07/08 - H13423 Netfinity 3500: 1801 PCI/PNP Errors w/ 2 ServeRAID II
- 98/07/08 - H125446 Netfinity 5500: BEEP CODE or LOST VIDEO upon adding MEMORY
- 98/07/09 - H124341 Netfinity 3500: Correct ADAPTEC DRIVERS in Serverguide 4.02+
- 98/07/13 - H164143 Netfinity 3500: EMC CLIP Removal to FIX FLOPPY DRIVE Error
- 98/07/21 - H164207 NETFINITY 5500: DIAGNOSTICS HANGS when LOADING DOS ASPI
- 98/07/21 - H164208 6892 / 6898 / 8644 / 8476 HORIZONTAL MOUNTING
- 98/07/22 - H164215 NETFINITY 3500: NOS INSTALL fails REBOOT on OPEN BAY SYSTEM
- 98/07/22 - H164216 HMM UPDATE: MISSING "DISPLAY PANEL SUPPORT" for PCSERVER 520
- 98/08/07 - H164352 SERVER may HANG with 2+ TOKEN RING / SMP / INTRANETWARE
- 98/08/07 - H164353 NETFINITY 5500: HANG with UNATTENDED BOOT / PASSWORD / OS/2
- 98/08/10 - H164358 UNEXPECTED REBOOT may OCCUR with A.S.M.A. on SOME SERVERS
- 98/06/03 - H164360 CORRECT CONCURRENT DRIVE SPIN-UP on POWER-UP SETTINGS
- 98/08/19 - H164427 NETFINITY 3500: OS/2 WARP SERVER SMP V4.0 INSTALL HANGS
- 98/08/20 - H164431 NETFINITY 7000: SERVERGUIDE CD#1 HANGS SYSTEM at BOOT
- 98/08/20 - H164433 A.S.M.A. MAY NOT BE DETECTED BY SERVER AFTER POWER OFF/ON
- 98/09/09 - H163649 PERFORMANCE ENHANCEMENTS for SERVERAID I and II ADAPTERS
- 98/09/14 - H164020 YEAR 2000: SERVERS that require a BIOS UPGRADE
- 98/09/15 - H163143 NETFINITY 7000 FRONT PANEL DISPLAYS UNREADABLE CHARACTERS
- 98/09/17 - H164726 CLIENT NOT CONNECTED after HOT-ADDING A 10/100 ETHERNET NIC
- 98/09/17 - H164732 MULTIPLE FORE ATM ADAPTERS do NOT WORK with NETWARE DRIVER
- 98/09/17 - H164735 REMOTE TERMINAL: DIAGNOSTICS not UPDATING DISPLAY STATUS
- 98/09/18 - H164699 SHARING SERIAL PORTS on the ASMA ADAPTER are NOT SUPPORTED
- 98/09/18 - H164722 SERVER DIAGNOSTICS will HANG if USB DEVICE is ATTACHED
- 98/09/18 - H164723 AIC78XX FAILED to LOAD in NT when USING SERVERGUIDE
- 98/09/18 - H164725 CERTAIN DIAGNOSTIC TESTS HANG when USB ENABLED
- 98/09/18 - H164729 NETFINITY 7000 M10: OS/2 WARP HANGS or TRAPS DURING INSTALL
- 98/09/18 - H164730 NETFINITY 5500: GETTING 1601 and 012991XX POST ERRORS
- 98/09/18 - H164731 SERVICE PROCESSOR DISKETTE is NOT CREATED in SERVERGUIDE
- 98/09/18 - H164733 RTC CLOCK DATE CHANGED when LOOPING DIAGNOSTICS OVERNIGHT
- 98/09/22 - H164721 NETFINITY SERVERS: CANNOT CREATE the FILE A:\RAIDEVT.LOG
- 98/09/22 - H164727 SERVERAID DRIVER FAILURE during NW4.11 INSTALL
- 98/09/22 - H164734 NETWARE ABENDS RUNNING SYSTEMS MANAGEMENT PROCESSOR DRIVER
- 98/09/22 - H164782 HARDSET INTERRUPTS changing AFTER REBOOT
- 98/09/25 - H164409 NETFINITY 5500: with 256MB REGISTER SDRAM
- 98/09/25 - H164729 NETFINITY 7000 M10: OS/2 WARP HANGS or TRAPS DURING INSTALL
- 98/09/25 - H164781 HOTPLUG OR I²O is SUPPORTED, but NOT BOTH at SAME TIME
- 98/09/30 - H164824 SERVER RUNNING WINDOWS NT 4.0 may HANG during HEAVY FILE I/O
- 98/10/07 - H164870 NETFINITY 5500 & 5500-M10: NETWARE 4.11 SMP INSTALL PROBLEMS
- 98/10/13 - H164897 REMOTE CONNECTION LOST when RUNNING DIAGNOSTICS
- 98/10/13 - H164902 NETFINITY 5500 M10: BAD VRM is NOT INDICATED by SYSTEM LED
- 98/10/13 - H164905 ETHERNET DIAGNOSTICS FAILS if an EXTERNAL WRAP is ATTACHED
- 98/10/14 - H164900 AMBIENT OVER-TEMPERATURE FAILURE REPORTED INCORRECTLY
- 98/10/14 - H164901 POST SHOWS WRONG PROCESSORS after REPLACEMENT of a PROCESSOR
- 98/10/14 - H164906 REVISION LEVEL of DIAGNOSTICS in SYSTEM SET-UP NEVER CHANGES
- 98/10/14 - H164907 "90" POWER SYSTEM ERRORS NOT REPORTED on the FRONT PANEL
- 98/10/14 - H164908 INABILITY to HOT-ADD PCI DEVICES with 4GB of MEMORY
- 98/10/20 - H164980 TRAP 0003 OCCURS with UNATTENDED BOOT using OS/2 WARP
- 98/10/21 - H084762 SYSTEM HANGS using PREFORMATTED DISKETTE for ERROR LOGGING
- 98/10/21 - H164982 UNABLE to UPDATE SERVICE PROCESSOR / POST ERROR 01299181
- 98/10/21 - H165005 NETWARE not CONNECTING with 10/100 FAULT TOLERANT ADAPTER
- 98/10/21 - H165120 10/100 ETHERJET PCI ADAPTER: POOR PERFORMANCE, DISCONNECTS
- 98/10/21 - H165420 NETFINITY 5500: RAID OPTIONAL SCSI CABLE for EXTERNAL DEVICE
- 98/10/21 - H165425 NETFINITY 5500: RUNNING DIAGNOSTICS TESTS causes HANG
- 98/10/21 - H165796 ON/OFF SWITCH CABLE DETECT NOT WORKING
- 98/10/22 - H165018 DOS FDISK REPORTS no FIXED DISKS PRESENT with PCI RAID
- 98/10/26 - H164979 INCORRECT MOVEMENT of SMU's MENU SELECTION BAR during TELNET
- 98/10/28 - H165049 SSA RAID ADAPTER RESTRICTED to RAID 5 with OVER 2GB OF RAM
- 98/10/28 - H165111 NETFINITY 5500: WINDOWS NT INSTALLATION FAILS, SYSTEM HALTED
- 98/10/30 - H165084 CONFIGURING SCSI REPEATERS in the 3518 ENCLOSURE
- 98/11/02 - H165117 NETFINITY 5000: VRM ERROR - SYSTEM HELD in STANDBY MODE
- 98/11/02 - H165123 LOGIN to SYSTEM MANAGEMENT UTILITY with a WEB BROWSER FAILS
- 98/11/02 - H165124 NETFINITY 5000: PEER to PEER ADAPTER CARD PERFORMANCE
- 98/11/02 - H165135 INCORRECT POWER SUPPLY STATUS, after ADDING a POWER SUPPLY
- 98/11/02 - H165140 PROCESSOR NOT REPORTED correctly, AFTER a PROCESSOR goes BAD
- 98/11/02 - H165149 SERVICE PROCESSOR WILL TAKE CONTROL of THE SHARED PORT
- 98/11/02 - H165150 MEMORY ERRORS NOT IN LOG if "ALL BANKS" MEMORY TEST SELECTED
- 98/11/03 - H165128 SCO 5.0.5 & IBM PCI T/R ADAPTER SHARING INTERRUPTS
- 98/11/04 - H165142 NETFINITY 5000: ADAPTER CARDS with PCI BRIDGE (LIMITATIONS)
- 98/11/03 - H165144 ADAPTER IRQ CHANGES / ADAPTER NOT VISIBLE in CONFIGURATION
- 98/11/03 - H165145 FREE IRQ'S on 320, 520, and 330'S, for PCI DEVICES
- 98/11/30 - H165127 DBCS CORRUPTION with OS/2 WARP SERVER SMP 4.0J
- 98/11/02 - H165467 ON/OFF SWITCH NOT WORKING after SYSTEM CATASTROPHIC FAILURE
- 98/12/03 - H164903 NETFINITY 5500 M10: ERROR LED RESET to OFF
- 98/12/04 - H165405 SERVER & NETWARE V4.11 HANGS on MULTIPLE SERVERAID ADAPTERS
- 98/12/04 - H165409 V72 FIRMWARE HELPS 'DETACHED LEADER' on DLT TAPE DRIVES
- 98/12/04 - H165466 PROCEDURE for BACK-LEVELING SERVERAID FIRMWARE/BIOS
- 98/12/09 - H165468 MICROSOFT CLUSTER SERVER RESOURCES FAIL AFTER APPLYING SP4
- 98/12/10 - H164978 CHKDSK reports FALSE FILE READ ERRORS
- 98/12/11 - H165493 SERIALRAID ADAPTER: use NT SP4 and 6450 ADAPTER UCODE
- 98/12/14 - H163838 Installing IBM Netfinity High Availibility CLUSTER
- 98/12/15 - H165264 PUSHDOWN TAB in BAY 3 INTERFERES with TAPE DRIVE FUNCTION (Netfinity 3000)
- 98/12/22 - H061134 SERVERAID LOG MUST BE CLEARED after FIRMWARE/BIOS is UPDATED
- 98/12/28 - H165545 NETFINITY'S ASM DIMM INFORMATION DISPLAY ERROR
- 98/12/29 - H165694 SYSTEM HANGS DURING INSTALLATION OF OS/2 SMP
- 98/12/29 - H165797 UPDATING the IBM NETFINITY CLUSTER ENABLER SOFTWARE
- 98/12/30 - H165582 SP may ISSUE OVER VOLTAGE ALERT due to PS COMPATIBILITY
- 1999 -
- 99/01/05 - H001448 FALSE ERROR MESSAGE when RESTARTING SERVICE PROCESSOR
- 99/01/08 - H003324 ORACLE JAVA and SYMBIOS SYMPLICITY requires 1MB VRAM
- 99/01/14 - H164728 I20 WILL NOT WORK in CONJUNCTION with HOT PLUG
- 99/01/15 - H165402 When RUNNING DOWN LEVEL DIAGS. I2C TEST and SP TESTs FAIL
- 99/01/15 - H165703 SYSTEM SHUTS DOWN WHEN PCI CARD is REMOVED OR ADDED
- 99/01/15 - H165760 PCI TOKEN-RING ADAPTER-2 POWER OFF/ON PROBLEM
- 99/01/18 - H165693 NETWARE/NT INSTALLATION FAILS with ADAPTEC AAA131 ADAPTER
- 99/01/18 - H165698 9086001 - SHARING IRQS MAY CAUSE UNPREDICTABLE RESULTS
- 99/01/18 - H165695 ALERT TIME NOT REPORTED CORRECTLY on NETFINITY MANAGER
- 99/01/19 - H165713 INCORRECT FRU NUMBER listed in EARLY VERSION of 8661 HMM
- 99/01/19 - H165714 NOS FAILS to BOOT when SERVER is REBOOTED DURING REBUILD
- 99/01/19 - H165715 REBUILD USING SERVERAID ADMIN UTILITY FAILS USING HIGH ID
- 99/01/21 - H132024 174 POST ERROR and MICROPROCESSOR ERROR in DIAGNOSTIC
- 99/01/21 - H165786 I386 ERROR INSTALLING NETWORK ADAPTERS under WINDOWS NT
- 99/01/22 - H004976 NETFINITY RACK has NO PLANT CODE PREFIX as PART OF S/N
- 99/01/22 - H165583 NETFINITY 5500 M10 PLANAR BATTERY
- 99/02/01 - H165806 8639-OEX: VIDEO on SEVERAL BECOMES CORRUPTED
- 99/02/01 - H165838 NO VIDEO DURING POST after REBOOT OR POWER CYCLE
- 99/02/04 - H162123 NETFINITY 3000: some CUSTOMERS may REQUIRE 2-DROP IDE CABLE
- 99/02/08 - H165839 NETFINITY 7000 M10 FAN MONITOR STATUS NOT CORRECT
- 99/02/09 - H165518 DIFFERENCE BETWEEN 2 VRMS made by DIFFERENT VENDORS
- 99/02/09 - H015613 BIOS 27A and 28A COULD CORRUPT SYSTEM TIME AND DATE
- 99/02/09 - H165897 NETFINITY 5500 & 5500-M10: USE OF SSA ADAPTERS
- 99/02/10 - H165852 NETFINITY 7000-M10: PROCESSOR FRU PART QUALIFICATION
- 99/02/10 - H165854 DATA CORRUPTION ON HPFS386 DRIVES OR BOOT FAILURE
- 99/02/10 - H165855 HANG OCCURS in WINDOWS NT with A PLEXTOR CD-ROM TOWER
- 99/02/10 - H165892 ORACLE TERMINATES WITH FAILURE OF NODE IN A TWO-NODE CLUSTER
- 99/02/10 - H165894 ORACLE ENTERPRISE MANAGER ONLY SEE DATABASES AS INDIVIDUAL
- 99/02/10 - H165895 CLIENTS CAN NOT CONNECT to an ORACLE PARALLEL SERVER NODE
- 99/02/10 - H166815 NT REPLICATED INSTALLATION IN SOFTWAREGUIDE 4.1 WILL STOP
- 99/02/11 - H165893 ORACLE ENTERPRISE MANAGER SHOWS DATABASE as NOT STARTED
- 99/02/11 - H166814 CANNOT DELETE PARTITION USING DOS FDISK
- 99/02/17 - H165896 HANG OCCURS in WINDOWS NT with a PLEXTOR CD-ROM TOWER
- 99/02/17 - H165927 SERVERAID II with NVRAM BATTERY CACHE PROBLEMS
- 99/03/24 - H166166 WINDOWS NT 4.0 WILL NOT INSTALL WITH 4GB OF SYSTEM MEMORY
- 99/03/25 - H166167 CORRECTION TO THE FIBRE CHANNEL PCI ADAPTER USERS GUIDE
- 99/03/26 - H166162 HANGS ON WINDOWS NT 4.0 AND TERMINAL SERVER 4.0
- 99/03/26 - H166163 S3 VIDEO DRIVER MAY NOT LOAD WITH SOME COMM ADAPT
- 99/03/26 - H166165 NETFINITY 7000 OR PC SERVER 704: PERFORMANCE PROBLEMS
- 99/03/29 - H166168 NETFINITY ESCON: PROBLEMS WITH SERVICE PACK 4
- 99/03/29 - H166172 MULTI-SERVERAID: MISCELLANEOUS EVENTS OCCUR IN THE EVENT LOG
- 99/03/29 - H166314 PC SERVER 720: PROBLEM AFTER REPLACING PLANAR OR BRIDGE CARD
- 99/03/30 - H166171 9086-001: HANGS UNLOADING PBXAAPI OR SHUTTING DOWN NETWARE
- 99/03/31 - H166305 SYSTEM CLOCK (TIME) IS AFFECTED AFTER BOOTING FROM CD
- 99/03/31 - H166313 STOP SSA EVENT LOGGER BEFORE HOST SOFTWARE INSTALL
- 99/04/14 - H166306 PCI FIBRE CHANNEL ADAPTER: STATEMENT OF SUPPORT
- 99/04/15 - H166308 NETFINITY 5000: WINDOWS NT INSTALLATION FAILS, SYSTEM HALTED
- 99/04/16 - H136301 PC SERVER325/330: PLANNING FOR A ROLLOUT - BATTERY ISSUES
- 99/04/16 - H166309 UNABLE TO INSTALL WINDOWS NT 4.0 FROM CDROM BOOT
- 99/04/16 - H023099 NETFINITY CLUSTER PACK: YEAR 2000 UPDATES ARE AVAILABLE
- 99/04/19 - H166357 1962 POST CAUSED BY INCORRECT INSTALLATION OF SCSI CABLE
- 99/04/22 - H166366 NETFINITY 5000 BIOS 28A REQUIRED FOR ADVANCED SERIALRAID/X
- 99/04/28 - H166374 PC SERVER 320/520 WILL NOT BOOT DIAGNOSTIC DISKETTE
- 99/04/28 - H166375 FAILOVER ISSUES: SSA CLUSTER ADAPTER AND HOST SW 1.06, 1.07
- 99/04/28 - H166817 NETFINITY 3000: SERVERGUIDE 4.1 DISKETTE CREATION FAILS
- 99/05/04 - H166370 NO DRIVER FOR ADAPTEC AHA-2940U2W SCSI-2 ADAPTER OPTION
- 99/05/04 - H166482 IBM NETFINITY 10/100 ETHERNET FOR NW411 WON'T LOAD
- 99/05/04 - H127443 TRAPS UNDER WINDOWS NT 4.0 RUNNING SMP
- 99/05/05 - H166436 ESCON CANNOT HAVE MAX BTU LARGER THAN 4105 FOR FOR 2.1 NODES
- 99/05/05 - H166560 POOR SSA DISK WRITE PERFORMANCE
- 99/05/06 - H166433 NETFINITY SERVER HANGS ON MAINFRAME IPL WITH ESCON INSTALLED
- 99/05/07 - H166447 POST ERROR "01299110 CPU X HAS AN INVALID SERIAL NUMBER"
- 99/05/14 - H166494 NETFINITY 5000: REMOTE FLASH FAILS W/ WRONG DISKETTE MESSAGE
- 99/05/14 - H09289 UNABLE TO RUN "ENHANCED" POST IF POST WATCHDOG TIMER IS SET
- 99/05/18 - H166509 NETFINITY 5000: RAS ADAPTERS ONLY WORK IN SLOT-5
- 99/05/19 - H166508 NETFINITY 7000-M10: POST DISPLAYS ERRORS BUT MEMORY WORKS OK
- 99/05/19 - H166544 INVALID SYSTEM DATE IN PS/2 MODEL 95 RUNNING OS/2
- 99/05/28 - H165407 REPLACING PLANARS WITH PENTIUM II, III, & CELERON PROCESSORs
- 99/06/01 - H166497 RESOURCE CONFLICTS W/ SHARED IRQ'S RUNNING OS/2 WARP SERVER
- 99/06/02 - H166164 NETFINITY 7000: DIAGNOSTICS REPORT FALSE ERRORS
- 99/06/08 - H166956 NT DISK ADMINISTRATOR MAY CHANGE THE PARTITIONS TABLE
- 99/06/17 - H166750 NETFINITY 3000: ADAPTER CARDS MAY LOOSEN IF SERVER IS MOVED
- 99/06/22 - H054408 NETFINITY 7000-M10 500/550MHZ PROCESSOR JUMPER SETTINGS
- 99/06/29 - H09309 EXP10 / EXP15: RED DRIVE LIGHTS TURNED ON
- 99/06/29 - H166727 5V REGULATOR CARD can EXHIBIT a CAP BURNOUT FAIL
- 99/06/29 - H166818 NETFINITY 3500: CAN NOT EXECUTE OS/2 MEMORY DUMP
- 99/06/30 - H09570 NETFINITY 5000: ISDN ADAPTERS ONLY WORK IN SLOT-5
- 99/07/07 - H166359 ERROR DURING INSTALLATION OF SERVERAID CLUSTER SOLUTION
- 99/07/09 - H166850 NETFINITY 5500: RS485 CONNECTION CANNOT BE ESTABLISHED
- 99/07/11 - H164662 PLANAR BOARDS not REPLACED PROPERLY
- 99/07/21 - H166965 SERVERAID: HOT SWAP REBUILD DOES NOT WORK AUTOMATICALLY
- 99/07/22 - H167002 NETFINITY 7000 M10 FAN MONITOR STATUS NOT CORRECT
- 99/07/27 - H166984 NT FAILS TO INSTALL: MESSAGE "INACCESSIBLE_BOOT_DEVICE"
- 99/07/28 - H13992 NETFINITY 7000-M10: I/O PLANAR SHORTING EXPOSURE
- 99/07/28 - H166988 IPSSEND UNDER NT 4.0 CAN CAUSE BLUE SCREEN, HANG OR REBOOT
- 99/07/29 - H166991 NETFINITY 7000-M10: UPDATING NEW POWER BACKPLANE TO CODE 15
- 99/07/29 - H165805 NETFINITY 3500: NT 4.0 does NOT LOAD or INSTALL
- 99/07/30 - H167030 OS/2 SMP 4.0: SYS1919 ERROR WHEN INSTALLING FROM SERVERGUIDE
- 99/07/30 - H105023 NETFINITY 3500-M10: OS/2 WARP SERVER PROBLEM W/ NETSERVR.EXE
- 99/07/31 - H167144 SCO UNIXWARE 7 FAILS TO INSTALL - 2ND CD IS NOT RECOGNIZED
- 99/07/31 - H015647 SERVERAID ADMINISTRATION AND MONITORING DATE DISPLAY PROBLEM
- 99/08/05 - H166964 NETFINITY & PC ANYWHERE: S3 VIDEO NOT WORKING CORRECTLY
- 99/08/06 - H166994 NETFINITY 5000 AND 5500: PROCESSOR'S PARTS MAY BE MISLABELED
- 99/08/06 - H164212 NETFINITY 3500: INTRANETWARE DRIVER ISSUE with PCI SLOT #1
- 99/08/11 - H08960 NETFINITY 5500: RACK RAIL KIT (28L0646)
- 99/08/11 - H164701 NETFINITY3000: SERVERAID 3X are ONLY SUPPORTED in PCI SLOT 3
- 99/08/12 - H122173 MSCS & SERVERAID: IPSHAHTO.EXE MAY FAIL TO MOVE RESOURCES
- 99/08/12 - H024937 NT INSTALL REPORTS INCORRECT HDD SIZE
- 99/08/12 - H162579 NETFINITY 3500 - PLANAR REPLACEMENT and BIOS UPDATE procedure
- 99/08/19 - H166358 SERVERAID WITH MSCS: DRIVE REBUILD PROCESS CAN STOP
- 99/08/19 - H161972 TAPE DRIVE CLEANING STRATEGIES
- 99/08/19 - H024933 SERVICES FAILED TO START INSTALLING NT 4.0 USING SERVERGUIDE
- 99/08/24 - H022941 SYSTEM MANAGEMENT ADAPTER: SYSTEM MAY NOT START
- 99/09/01 - H166999 SYSTEM GENERATES FALSE FAN ALERT
- 99/09/03 - H022938 NETFINITY 7000-M10: SYSTEM MAY EXHIBIT CP66 HANG
- 99/09/03 - H03144 MACHINE STOPS DURING BOOT AFTER ADDING A SCSI ADAPTER
- 99/09/08 - H025613 4-WAY PROCESSOR UPGRADE: NO VIDEO AFTER BIOS UPGRADE
- 99/09/21 - H201068 NETFINITY 3500: OS/2 TRAPS DURING INSTALLATION
- 99/09/21 - H167294 BLUE SCREEN WITH STOP 0X0000009C UNDER NT OR TERMINAL SERVER
- 99/09/22 - H167154 NEW MICOCODE FOR SOME 80PIN 9.1GB AND 18.2GB HARD DRIVES
- 99/09/27 - H166928 NETFINITY 5600: PEER TO PEER ADAPTER CARD PERFORMANCE
- 99/09/28 - H167301 8MM MAMMOTH TAPE DRIVE MUST BE CLEANED AFTER USING MP MEDIA
- 99/09/28 - H167333 IBM SSA RAID CLUSTER ADAPTER SOFTWARE UPGRADE
- 99/09/28 - H001587 DDS/3 TAPE DRIVE 01K1282 requires FIRMWARE UPDATE 7.35E
- 99/09/28 - H167338 RED HAT LINUX 6.0: SMP NOT DETECTED DURING INSTALL
- 99/09/28 - H167340 SERVER INSTABILITY, HANGS, UNABLE TO INSTALL NOS
- 99/09/28 - H167342 DO NOT USE OS/2 VIDEO DRIVERS ON S3 VIDEO DRIVER CD
- 99/09/28 - H167350 WINDOWS NT MAY CRASH WHILE RUNNING FINDFAST.EXE
- 99/09/28 - H167697 NETFINITY 5600: REMOTE POST PERFORMANCE ENHANCEMENT
- 99/09/29 - H167343 OS/2 WILL NOT RECOVER FROM BLACKOUT WHEN APM IS ENABLED
- 99/09/29 - H167346 NETFINITY 5500: DIAGNOSTICS REPORT FAILURE WITH SERVERAID
- 99/09/29 - H165581 OS/2 VIDEO CORRUPTION in TEXT MODE using VGA DRIVER
- 99/09/30 - H167345 CANNOT CREATE A PARTITION GREATER THAT 1 GB DURING NT SETUP
- 99/09/30 - H167349 ADVANCED SYSTEM MANAGEMENT PROCESSOR DRIVER: FAILS INSTALL
- 99/09/30 - H167356 5500: 2940UW REV B SHARING INTERRUPTS WITH ONBOARD SERVERAID
- 99/10/05 - H164724 BIOS REPORTS INCORRECT PROCESSOR SPEED
- 99/10/05 - H167385 SYSTEM WILL NOT SEE SCSI DEVICES, AFTER PLANAR REPLACEMENT
- 99/10/07 - H167384 EXP 15: BAD DATA AFTER INITIAL DATA INQUIRY OF SCSI ADAPTER
- 99/10/11 - H167488 1805 POST ERROR WITH NETFINITY 10/100 ETHERNET ADAPTER 2
- 99/11/09 - H062919 7000-M10: CTL-ALT-DEL WILL NOT RESET HOTPLUG FUNCTION
- 99/11/10 - H043322 SERVER REBOOTS AFTER AN NT BLUE SCREEN STOP ERROR MESSAGE
- 99/11/17 - H167341 POST ERRORS, VPD AND 1601 SERVICE PROCESSOR ERROR
- 99/11/18 - H167813 NETFINITY 5000: MAY NOT BOOT TO OPERATING SYSTEM
- 99/11/18 - H167814 SERVERAID: NOS HANGS, TRAPS, BLUE SCREENS, PANICS, OR ABENDS
- 99/11/18 - H167816 COMMAND TIMEOUTS LOGGED IN WINDOWS NT WITH 7200 RPM 36GB HDD
- 99/11/23 - H167812 TCP/IP SECURITY FIX FOR WINDOWS NT 4.0
- 99/11/23 - H167848 INTERMITTENT SYSTEM HANG WITH SERVER RUNNING NETWARE
- 99/11/30 - H131159 CI SLOT DOES NOT POWER ON DURING HOT ADD
- 99/11/30 - H164098 Netfinity 5500: FIXES for Incomplete MICROCODE Flash
- 99/11/30 - H167295 NEW MICROCODE FOR SOME 68PIN 9.1GB AND 18.2GB HARD DRIVES
- 99/11/30 - H167884 TR4 FIRMWARE UPDATE AVAILABLE FOR IDE TR4 AND SCSI TR4(STT)
- 99/12/01 - H097076 NETWARE VOLUMES RANDOMLY DISMOUNT ON 9GB AND 18GB HDD
- 99/12/03 - H167940 RED HAT 6.1 INSTALL: WILL NOT BOOT WITH 2 SCSI CONTROLLERS
- 99/12/07 - H20340 LARGE RAID LOGICAL DRIVE FAILS UNDER UNIXWARE 7.1
- 99/12/14 - H201108 NETFINITY 5600: CPU REPLACEMENT RESULTS IN NO VIDEO OR ERROR
- 99/12/15 - H167887 BIOS DISPLAYS MEMORY SIZE WITH 4GB OR MORE
- 99/12/16 - H201057 NETFINITY 5600: MAY REBOOT LOOPING ON QUICK TEST DIAGNOSTICS
- 99/12/16 - H201063 NETWORK PORT ASSIGNMENTS DON'T MATCH NT NETWORK PROPERTIES
- 99/12/17 - H201066 SERVICE PROCESSOR UTILITY: SCHEDULED POWER ON FAILS
- 99/12/17 - H201069 AMD ETHERNET NT DRIVER V4.10 GENERATES WARNING IN EVENT LOG
- 99/12/17 - H201072 ASM PCI ADAPTER OPTION: MUST USE EXTERNAL POWER SUPPLY
- 99/12/17 - H201088 MSCS MULTINODE FAILOVER: MAY REQUIRE CHCS.DLL PATCH
- 99/12/20 - H022475 NETFINITY 3000: ADAPTEC DRIVER SHOULD BE UPDATED AFTER FLASH
- 99/12/20 - H201086 ETHERNET DRIVERS FOR UNIXWARE 7.0 AND 7.1
- 99/12/20 - H201087 SERVERAID: BATTERY BACKUP WRITE CACHE ERROR
- 99/12/22 - H201112 NETFINITY FIBRE CHANNEL - POWER ON/OFF PROCEDURE
- 99/12/23 - H167344 NETFINITY 1000/3000: PCI ERROR CAUSED BY ADDING ISA ADAPTER
- 99/12/23 - H167938 PCI HOT SWAP LATCH DIAGNOSTIC: DO NOT RUN W/ ADAPTER PRESENT
- 99/12/23 - H201109 S3 VIDEO: DIFFERENT DRIVERS NEEDED FOR DIFFERENT REVISIONS
- 99/12/24 - H201065 NETFINITY 5600: POSSIBLE POWER-ON PROBLEM INTERNAL
- 99/12/28 - H167339 NOS HANGS OR TRAPS RUNNING WITH SERVERAID 3L
- 99/12/30 - H201165 NETFINITY FIBRE: RECOVERY PROCEDURES FOR FAILED DRIVES
- 2000 -
SCSI - RAID
- 1999 -
Server - ECAs
RAID Controller Firmware Chart
Back to
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.