Power-On Password
A power-on password denies access to the system by an unauthorized user
when the system is powered on. When a power-on password is active, the
password prompt appears on the screen each time the system is powered on.
The system starts after the proper password is entered. See 'Power-on Password'
for more information about how to change, remove and set password in BIOS Setup.
In some cases, you might be required to service a system with an active and
unknown power-on password. To clear a password from the system, follow these steps.
-WARNING- Do not attempt these steps with the power cord plugged into the
electrical outlet.
The power supply maintains +5 Vdc of standby power when the power cord is plugged.
System damage might result if the power cord is not unplugged during testing.
Machine Type 2139: Set switch 2 of S1 to the ON position to bypass
password check process.
See 'Machine Type 2139 System Board Jumpers and Connectors'.
Machine Type 2153/K6: Set switch B2 of SW3 to the OFF position to bypass
password check process.
See 'Machine Type 2153/K6 System Board Jumpers and Connectors'.
Machine Type 2153/Celeron: Set switch 1 of SW1 to the ON position to bypass
password check process.
See 'Machine Type 2153/Celeron System Board Jumpers and Connectors'.
Machine Type 2158: Set switch 2 of SW2 to the OFF position to bypass
password check process.
See 'Machine Type 2158 System Board Jumpers and Connectors'.
Machine Type 2163: Set switch 5 of SW1 to the ON position to bypass
password check process.
See 'Machine Type 2163 System Board Jumpers and Connectors'.
Machine Type 2139: Set switch SW2 of S1 to the OFF position to enable
password check process. See 'Machine Type 2139 System Board Jumpers and Connectors'.
Machine Type 2153/K6: Set switch B2 of SW3 to the ON position to enable
password check process. See 'Machine Type 2153/K6 System Board Jumpers and Connectors'.
Machine Type 2153/Celeron: Set switch 1 of SW1 to the OFF position to enable
password check process. See 'Machine Type 2153/Celeron System Board Jumpers and Connectors'.
Machine Type 2158: Set switch 2 of SW2 to the ON position to enable
password check process. See 'Machine Type 2158 System Board Jumpers and Connectors'.
Machine Type 2163: Set switch 5 of SW1 to the OFF position to enable password
check process. See 'Machine Type 2163 System Board Jumpers and Connectors'.
To reinstall the password, the user must enter a password in the
Setup Utility.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.