Please see the LEGAL - Trademark notice.
LED
STATE
1 0
On
OK
On
1 - 4
see Note
Wrap RI
On - If RI module is optical fiber
Off - If RI module is copper
Wrap RO
On - If RO module is optical fiber
Off - If RO module is copper
RI Module
On
RO Module
On
Error Code Display
Off
Note If the base unit has an Optical Fiber Module installed, make sure that the optical fiber test
cable is inserted in the receptacles.
The green LED will be lit next to the number of each LAM that is connected to the base unit and is operating correctly.
The yellow LED will be lit next to the number of each LAM that is defective or incorrectly connected to the base unit.
Remove the test cable from the Optical Fiber Modules, if present
Re-cable the base unit to the token-ring network
Notify the network administrator that the base unit is operational.
MAP START
|001|
+---+
Has the customer used the IBM Token-Ring Network Determination Guide
to isolate the problem to this IBM 8230 Base Unit ?
+---+
Yes No-+002|Refer the network administrator to the IBM Token-Ring
| +---+Network Problem Determination Guide to isolate the
| problem.
| Continue with Step 003 if you have isolated the
| problem to this IBM 8230.
+-+-+
|003|
+---+
- Check the 4/16 Mbps switch setting on the front of the base unit.
- Be sure that the setting matches the data rate of the ring.
- Turn on the power of the IBM 8230, and wait 60 seconds.
Note : DO NOT turn off the power of the base unit unless you
are instructed to do so. Turning off the power of the base unit
will disrupt all users connected to this base unit.
IS an X'8X' status code displayed in the error code display ?
+---+
Yes No-+004| Go to Step 006
| +---+
+-+-+
|005|
+---+
- Replace the Processor Board
- Test the IBM 8230 as described in this chapter (above the MAP)
+---+
|006|
+---+
Is an error code displayed ?
+---+
Yes No-+007| Go to Step 011
| +---+
+-+-+
|008|
+---+
Is the error code one of the following codes ?
20 2A 30 3A 31 3B
22 2C 32 3C 33 3D
24 2E 34 3E 35 3F
26 36 37
28 38 39
+---+
Yes No-+009| Locate the displayed Error Code in the below Table.
| +---+ Perform the action provided.
+-+-+
|010|
+---+
- LAM is not correctly connected to the base unit.
- LAM is defective.
- Processor Board is defective
- Power connector card is defective.
+---+
|011|
+---+
Are any of the LEDs lit ?
+---+
Yes No-+012| - Base units power switch is off.
| +---+ - AC voltage is missing at the wall outlet.
| - Power cord is not connected correctly.
| - AC voltage switch setting is incorrect.
| - Power Supply cable is not plugged into the
| Processor Board.
| - Display Card cable is not plugged into the
| Processor Board.
| - Power Supply is defective.
| - Processor Board is defective.
+-+-+ - Display card is defective.
|013|
+---+
Is the OK LED lit ?
+---+
Yes No-+014| Go to Step 018
+---+ +---+
|015|
+---+
Is the IBM 8230 Base Unit in a wrap state ?
Locate the RI and RO Wrap LEDs. If one or both of this LEDs is lit,
then the IBM 8230 Base Unit is in a wrap state of Wrap RI, Wrap RO,
or Wrap RI/RO.
+---+
Yes No-+016| Go to Step 021
+---+ +---+
|017|
+---+
- There is a problem with the token-ring network segment on the RI
or RO side of the IBM 8230 Base Unit.
- There is a problem with the Copper or Optical Fiber Module.
- There is a problem with the Processor Board.
- The IBM LAN Network Manager or Maintenance Facility has issued a
wrap command.
+---+
|018|
+---+
Are the Copper or Optical Fiber Module LEDs lit and no other LEDs lit ?
+---+
Yes No-+019| - Replace the Processor Board.
| +---+ - Test the IBM 8230 as described in this chapter
| (above the MAP)
+-+-+
|020|
+---+
- Replace the Display card
- Test the IBM 8230 as described in this chapter (above the MAP)
+---+
|021|
+---+
Is the LAM connected to the base unit, and is the LAM LED on the
front of the base unit off ?
+---+
Yes No-+022| Have soft errors been detected (e.g. by Ring Diags
| +---+ IBM LAN Manager, or some other program) ?
| +---+
| Yes No-+023| Notify the network administrator
| | +---+ that the IBM 8230 Base Unit is
| | operational.
| +-+-+
| |024| Anything internal to the IBM 8230 Base Unit
| +---+ but most likely the Processor Board is defective.
- Display card is defective.
- LAM is defective
- Processor Board is defective.
Error and Status Codes
Processor Board Error or Status Code.
Error Code in Hex
Type of Error or Status
Action
80-8F
Initialization in Progress
None
90
Error Stack Overflow
Test the 8230
E0
Control Processor Error
Proc.-Board
E4
Control Processor Error
Proc.-Board
E8
Control Processor Error
Proc.-Board Power-Supply
EC
Control Processor Error
Proc.-Board
F4
Internal Hardware Error
Wrap-Plug Media-Filter
F8
Controlled Access Unit Check
Proc.-Board
Remote Program Update Error or Status Codes.
Error Code in Hex
Type of Error or Status
Action
11
Finding Microcode Loader
none
12
Transferring Microcode Data
none (20 minutes)
13
Microcode Update complete
none
14
Microcode Update Alert
none
A1
Microcode Checksum Error
correct u-code ?
A2
Microcode Loader Not Found
reload u-code
A3
Microcode Update File Not Found
correct u-code ?
A4
Unsuccessful Microcode Load
correct u-code ?
Medium Access Control (MAC) Processor Error Codes.
(Reseat all Processorboard components / check Voltage)
Error Code in Hex
Type of Error or Status
61-63
8230 Adapter Error (1st MAC Error)
65-67
8230 Adapter Error (1st MAC Error)
69-6B
8230 Adapter Error (1st MAC Error)
6D-6F
8230 Adapter Error (1st MAC Error)
71-73
8230 Adapter Error (1st MAC Error)
75-77
MAC Toggle Error (1st MAC Error)
E1-E3
8230 Adapter Error (2nd MAC Error)
E5-E7
8230 Adapter Error (2nd MAC Error)
E9-EB
8230 Adapter Error (2nd MAC Error)
ED-EF
8230 Adapter Error (2nd MAC Error)
F1-F3
8230 Adapter Error (2nd MAC Error)
F5-F7
MAC Toggle Error
Lobe Attachment Module Error Codes.
(Reseat all Processorboard components / check Voltage / run Test
if still same error, then replace the Processor Board.)
Error Code in Hex
Type of Error
20
Lobe Attachment Module 1 Ring Data Error
21
Lobe Attachment Module 1 Cable Mismatch
22
Lobe Attachment Module 1 Communication Error
24
Lobe Attachment Module 2 Ring Data Error
25
Lobe Attachment Module 2 Cable Mismatch
26
Lobe Attachment Module 2 Communication Error
28
Lobe Attachment Module 3 Ring Data Error
29
Lobe Attachment Module 3 Cable Mismatch
2A
Lobe Attachment Module 3 Communication Error
2C
Lobe Attachment Module 4 Ring Data Error
2D
Lobe Attachment Module 4 Cable Mismatch
2E
Lobe Attachment Module 4 Communication Error
30
Lobe Attachment Module 1 Defective
31
Lobe Attachment Module 1 Defective
32
Lobe Attachment Module 1 Defective
33
Lobe Attachment Module 1 Defective
34
Lobe Attachment Module 2 Defective
35
Lobe Attachment Module 2 Defective
36
Lobe Attachment Module 2 Defective
37
Lobe Attachment Module 2 Defective
38
Lobe Attachment Module 3 Defective
39
Lobe Attachment Module 3 Defective
3A
Lobe Attachment Module 3 Defective
3B
Lobe Attachment Module 3 Defective
3C
Lobe Attachment Module 4 Defective
3D
Lobe Attachment Module 4 Defective
3E
Lobe Attachment Module 4 Defective
3F
Lobe Attachment Module 4 Defective
External Error Codes.
Error Code in Hex
Type of Error
Action
03
Ring Error Not Found
Proc.-Board
05
Frame Buffer Congestion
none
07
Internal Ring Recovery in Progress
none
B0
Duplicate Address MAC PO
check address
B1
Duplicate Address MAC PI
check address
B2
Duplicate Address MAC S
check address
Back to
Feel free - send a for any BUG on this page found - Thank you.