PCI Error Format and Error Codes/Messages



PCI Error Format and Error Codes/Messages

PCI Error Code Format

The following is an explanation of the encoded PCI error codes

Error codes are displayed on the screen as eight or sixteen digits as follows:

   DDDD DDS0 VVVVIIII
   ------+|| ---+---+
         |||    |   +--PCI Device ID
         |||    +------PCI Vendor Number
         ||+-Reserved (usually 0)
         |+PCI Slot Number (0 = System board)
         +-PCI Device Error


For example, PCI error code 005A210vvvviiii decodes as follows:

   005A 02   PCI device disabled due to Built-in Self Test failure
   1         The device is in PCI slot number one.
   0         Reserved.
   vvvv      Could be any number (PCI vendor ID)
   iiii      Could be any number (PCI device ID)


PCI Error Codes 
Error Code    FRU/Action
   00900100vvvviiii 1. System Board
   (System board PCI device  
   does not respond)  
   009002s0vvvviiii 1. If S <> 0, replace the PCI adapter.
   (PCI device Built-in Self     - or -
   Test failure)     If S = 0, replace the system board.
   009003s0vvvviiii 1. Run the PCI Utility or the Micro Channel
   (PCI device resource allocation     Change Configuration Utility to change
   failure. No resource available     system resource allocation.
   for the requested memory, I/O,  
   or C0000-DFFFF ROM addr. space)  
   009004s0vvvviiii 1. If S <> 0, replace the PCI adapter.
   (PCI device ROM checksum     - or -
   failure)     If S = 0, replace the system board.
   009005s0vvvviiii 1. Remove the unsupported PCI adapter
   (Unsupported PCI device)  
   009010s0vvvviiii 1. If S <> 0, replace the PCI adapter.
   (PCI data parity error)     - or -
      If S = 0, replace the system board.
   009011s0vvvviiii 1. If S <> 0, replace the PCI adapter.
   (PCI data parity error)     - or -
      If S = 0, replace the system board.
   009020s0vvvviiii 1. If S <> 0, replace the PCI adapter.
   (PCI addr. parity error)     - or -
      If S = 0, replace the system board.
   009030s0vvvviiii 1. If S <> 0, replace the PCI adapter.
   (PCI system error)     - or -
      If S = 0, replace the system board.


PCI Error Messages 
Error Message    FRU/Action
   PCI device(s) removed 1. One or more PCI add-in devices
   since last power up:     appears to have been removed since
   PCI vendor ID=xxxx, device     the last execution of POST
   ID=xxxx previously in slot x     This could be due to a catastrophic
      failure of the PCI device rather than its
      actual physical removal.
   PCI device(s) added 1. One or more PCI add-in devices
   since last power up:     appears to have been added since
   PCI vendor ID=xxxx, device     the last execution of POST
   ID=xxxx previously in slot x     It may have been moved from
      another slot. This is not an error.
      The device was enabled and had resources assigned.
   Unable to assign requested 1. A requested PCI resource (from the
   resources:     PCI Device Configuration Block) could not
   PCI vendor ID=xxxx, device     be assigned as requested due to a conflict
   ID=xxxx in slot x     with a non-PCI device or to a conflict with
      another requested PCI resource