Check/Verify
FRU/Action
1. Verify that the voltage-selector
switch is set for the correct
voltage.Correct the voltage-selector switch setting.
2. Check the following for proper
installation.
Power Cord
On/Off Switch connector
On/Off Switch Power Supply connector
System Board Power Supply connectorsReseat
3. Check the power cord for proper
continuity.Power Cord
4. Check the power-on switch
for continuity.Power-on Switch
If these are correct, check the following voltages.
System Board Connections (P1 / P2 and P11)
NOTE:
These voltages must be checked with the power
supply cables connected to the system board.
If the voltages are not correct, and the power cord is good, replace the
power supply.
If the voltages are correct, and the computer you are servicing has a
power supply connector on the riser card, check the following riser
card voltages.
Riser Card Connections (P10)
NOTE:
These voltages must be checked with the power
supply cable connected to the riser card.
If the voltages are not correct, and the power cord is good, replace the
power supply.