General Checkout (8551)



General Checkout

The diagnostic tests are intended to test only  IBM products. Non-IBM products, prototype cards, or modified options can give false errors and invalid computer responses.

 +---+
 |001|
 +---+
 DOES THE PROBLEM APPEAR TO BE A POWER SUPPLY FAILURE?
           +---+
  Yes   No-+002| Go to Step 006.
 +-+-+     +---+
 |003|
 +---+
 DO ALL SYSTEM-STATUS INDICATORS REMAIN OFF?
           +---+
  Yes   No-+004| Go to Step 006.
 +-+-+     +---+
 |005|
 +---+
 Go to 'Power Systems Checkout'
 -----------------------------------------------------------------------
 +---+
 |006|
 +---+
 - Power-off the computer and all external devices.
 - Check all cables and power cords.
 - Make sure no diskette is in the drive.
 - Power-on all external devices.
 - Power-on the computer and check for the following responses:
   1. All system-status indicators appear once for about 1 second.
      NOTE: Some indicators remain on and others go off
                       after 1 second.
   2. Memory test (the number increases.)
   3. One or two short beeps.
 DID YOU RECEIVE THE RESPONSES LISTED ABOVE?
           +---+
  Yes   No-+007| 1. If the memory count is incorrect,
   |       +---+    go to 'Memory Checkout'
   |
   |                Go to 'Symptom-to-FRU Index'
 +-+-+              If that does not correct the problem,
 |008|              go to 'Undetermined Problems'
 +---+
 - Press Ctrl+Alt+Del.  When the cursor moves to the
   upper right, press Ctrl+Alt+Ins to start the system
   program.  If the IBM logo screen does not appear, insert the backup
   Reference Diskette into the diskette drive and repeat this step.
   1. If you are not at the Main Menu, follow the instructions
      on the screen to advance to the Main Menu.
 If you cannot advance to the Main Menu, go to 'Symptom-to-FRU Index'
     - or -
 If that does not correct the problem, go to 'Undetermined Problems'
      NOTE:
      a. If the computer has an incorrect keyboard or numeric
         keypad response,
         go to 'External Keyboard/Auxiliary Input Device Checkout'
      b. If the printer has incorrect responses, go to 'Printer Checkout'
      c. If the external display has problems such as jittering, rolling,
         shifting, or being out-of-focus,
         go to 'External Display Self-Test'
   2. Press Ctrl+A and run the system checkout.
 IS THE LIST OF INSTALLED DEVICES CORRECT ?
           +---+
  Yes   No-+009| Go to 'Checking Installed Devices'
 +-+-+     +---+
 |010|
 +---+
 - Run the diagnostic tests.
 DID THE TEST IDENTIFY A FAILURE ?
 NOTE:
      If the test stops and you cannot continue, replace the last
      device tested.
     - or -
 If any POST error code appears, go to 'Symptom-to-FRU Index'
           +---+
  Yes   No-+011| You might have an intermittent problem:
   |       +---+
   |
   |  ° Check for damaged cables and connectors.
   |  ° Reseat all adapters, drives, and modules.
   |  ° Start an error log and run the tests multiple times.
   |  ° Check the power supply in use when the error is reported
   |    (see 'Power Systems Checkout'
   |  ° Check 'Symptom-to-FRU Index'. If this does not fix the problem,
   |    go to 'Undetermined Problems'
 +-+-+
 |012|
 +---+
 Go to 'Symptom-to-FRU Index'
 -----------------------------------------------------------------------