Tape Library Specifications


  Tape Library Specifications

  Physical Dimensions         Rack-Mount              Desktop
 ----------------------------------------------------------------------------
   Height                     8.75 in (22.23 cm)      9.25 in (23.50 cm)
   Bezel Height above Rack    0.75 in (1.91 cm)       - -
   Mounting Flange
   Overall Width             18.88 in (47.96 cm)     18.88 in (47.96 cm)
   Chassis Width             17.50 in (44.45 cm)      - -
   Chassis Width at          16.625 in (42.23 cm)     - -
   Mounting Rails
   Length                    26.50 in (67.31 cm)     26.50 in (67.31 cm)
   Weight (with two drives)  72 lb (32.73 kg)        92 lb (41.82 kg)
   Weight of Tape Drive       8.60 lb (3.91 kg)       - -
   Module
   Weight of Magazine with    6.60 lb (3.00kg)        - -
       10 Cartridges


Figure 7. Specifications for the Digital Linear Tape Library

                                                   Rack-Mount and Desktop
  Clearance      Front (for 3447 Tape Library      8.00 in. (20.32 cm) (for magazine replacement)
  Requirements   Model 105 and 7337 Tape
                 Library Models 305 and 306)
                 Front (for 3447 Tape Library      Sufficient clearance to open the rack door
                 Model 106)
                 Rear                              6.00 in. (15.24 cm)
                 Sides                             0
                 Top                               0
  Operating      Temperature                       +50F to +9SF (+1OC to +35C)
  Environment    Humidity                           20% to 80% (noncondensing)
                 Maximum Wet Bulb                  +73.4F (+23C)
                 Maximum Temperature Gradient      +11 C/hr
                 Maximum Humidity Gradient          10%/hr
                 Operating Altitude                 0 to 8000 ft (0 to 2438.4 m)
  Non-operating  Temperature                       -40F to +140F (-40C to +60C)
  Environment    Humidity                           20% to 80% (noncondensing)
                 Maximum Wet Bulb                   114.8F (+46C)
                 Maximum Temperature Gradient      +1OC/hr
                 Maximum Humidity Gradient          15%/hr
                 Non-operating Altitude             30,000 ft maximum (9144 m)
  Performance    Typical Power-on to Library         30 s
                 On-line
                 Maximum Power-on to Library         80 s
                 On-line
                 Typical Cartridge Inventory, Bar    30 s
                 Code Disabled
                 Typical Cartridge Inventory Bar    300 s
                 Code Enabled
                 Average Cartridge Access            13.5 s
  Power          Voltage                             100 to 240 V ac
  Requirements   Frequency                           48 to 64 Hz
                 Power Consumption by Library        130 W (typical; maximum with two DLT7000 tape
                                                            drives)
                 Power Consumption by                155 W (peak; maximum with two DLT7000 tape
                                                            DLT7000 Drive  drives)
 Power Supplies                                      One +5/+12/+24V power supply (The power Supply
                                                     provides power to the tape modules and robotics.)
 AC Connector   AC Power Connector                   Standard IEC 320 connector (The tape library is
 and Line Cord                                       shipped with a power cord for use in the USA.
                                                     For operation outside the USA, see Appendix A,
                                                     'Power Cables'.)


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.