Updating the System Diagnostic Programs


Updating the System Diagnostic Programs

Complete this procedure to update the system diagnostic programs.

  1.  Insert the IBM Netfinity 5500 M20 Diagnostic Update  Diskette 1 of 2  into the diskette drive.
  2.  Press Ctrl+Alt+Del to restart the server.  The system begins the power-on self-test (POST).

     Information similar to the following will appear on the screen.

      +----------------------------------------------------+
      |                                                    |
      |            Flash Utility                           |
      |                                                    |
      |Select one:                                         |
      |                                                    |
      |1. Update Diagnostics                               |
      |3. Exit                                             |
      |                                                    |
      |Enter       F1=Help       F3=Exit                   |
      |                                                    |
      +----------------------------------------------------+
     

  3.  Select: 1. Update Diagnostics and press Enter.
  4.  Select a language (0-7) from the list shown on the  next screen and press Enter to accept your choice.

     A message in your selected language similar to the following appears.

      +----------------------------------------------------+
      |                                                    |
      |                                                    |
      | Reading the flash image $0021000.us1               |
      |                                                    |
      |                                                    |
      +----------------------------------------------------+
     

     After this message appears, you will be prompted to  insert the IBM Netfinity 5500 M20 Diagnostic Update  Diskette 2 of 2  into the diskette drive.

  5.  Insert the diskette into the diskette drive and press Enter.
  6.  Press Enter to confirm that you want to update the  system diagnostic programs.

     A message similar to the following appears.

      +----------------------------------------------------+
      |                                                    |
      |                                                    |
      | Reading the flash image $0021000.us2               |
      |                                                    |
      |                                                    |
      +----------------------------------------------------+
     

     After this message, another message similar to the  following appears.

      +----------------------------------------------------+
      |                                                    |
      | The system diagnostic is being updated and it might|
      | take up to 5 minutes to complete. Do not power off |
      | or restart the system during this procedure.       |
      |                                                    |
      +----------------------------------------------------+
     

  7.  When the update is complete, a message similar to the following appears.

      +----------------------------------------------------+
      |                                                    |
      | Diagnostic Update Completed.                       |
      |                                                    |
      | Remove the diskette from the drive and press       |
      | Enter to restart the system.                       |
      |                                                    |
      +----------------------------------------------------+
     

  8.  Go to Updating the Advanced System Management Processor Code.