Predictive Failure Analysis

Predictive Failure Analysis

As with any electrical/mechanical device, there are two basic failure types:

  1.  Gradual performance degradation  of components can create a catastrophic drive failure.

     Predictive Failure Analysis performs the following remedial  operations:

     The data from periodic internal measurements is collected when data  sectors are accessed.

     Data scrubbing performs the following operations:

     accuracy of PFA The thresholds have been determined by examining the  history logs of drives that have failed in actual customer operation.  When PFA detects a threshold exceeded failure, the system administrator  can be notified through Netfinity Manager 5.0. The design goal of PFA is  to provide a minimum of 24 hours warning before a drive experiences  'catastrophic' failure.

  2.  A cable breaking, a component burning out, a  solder connection failing, are all examples of 'on/off' unpredictable  catastrophic failures . As assembly and component processes have  improved, these types of defects have been reduced but not eliminated.  PFA cannot always provide warning for on/off unpredictable failures.