Using the ServeRAID GUI-Based Configuration CD


Using the ServeRAID GUI-Based Configuration CD

To start the configuration program:

  1.  Insert the ServeRAID GUI-Based CD into the  CD-ROM drive, then, turn on the server.

     One of the following screens will appear:

  2.  Disable or Enable Read-Ahead Cache Mode:

     This choice is available in the Information mode only. When read-ahead cache is set to Enabled  (default setting), the ServeRAID adapter/controller transfers data from a disk to  its local cache in increments equal to the stripe unit size. This provides excellent  overall performance when workloads are steady and sequential. However, if the workload is  random or the system I/O requests are smaller than the stripe unit size, reading ahead to  the end of the stripe might degrade performance. When read-ahead cache is set  to Disabled , the ServeRAID adapter/controller transfers data from a disk to local  cache in increments equal to the system I/O request size, without reading ahead to the end  of the stripe.

  3.  Change the Rebuild Rate:

     This choice is available in the Information mode only. You can select this choice to set  the priority for Rebuild operations to High  (default), Medium ,  or Low .


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.