Identifying Problems through Status Indicators (Netfinity 7000-M10 - Type 8680)


Identifying Problems through Status Indicators

The server has status indicators to help you identify problems with some server components.
Status indicators are located on the following components:



System Component Status Indicators:

Status indicators on the I/O board, processor board, memory board, and the Advanced Remote Management Controller can help identify problems.
The indicators are lit during POST to ensure the indicators operate.
After POST completes, the indicators show the status of the component.

For the location of the status indicators, see:


Processor Board LEDs
Indicator    Description
   Microprocessor Bus    If activity on the microprocessor bus is
   Activity LED    present, the indicator for the slot is lit.
   
   Microprocessor VRM    If a VRM or processor fails or is missing,
   Status LED    the LED will light.
   
   Microprocessor    If proper termination of the microprocessor
   Termination LED    slot 4 is present, the indicator is lit.
   
   ERR 0 and    If either LED is on, see 'Symptom-to-FRU Index'
   ERR 1 LEDs    for an explanation.


Memory Board LED
Indicator    Description
   Memory Module    If a memory module is present and has
   Status LED    failed, the indicator for the slot is lit.


I/O Board LEDs
Indicator    Description
   Power On LED    If power to a PCI slot is present, the
     indicator for the slot is lit.
   
   Attention LED    The operating system defines the meaning
     of this indicator. Refer to the operating
     system documentation for more information.


Advanced Remote Management Controller LEDs
Indicator    Description
   Power On LED    If power to the Advanced Remote
     Management Controller is present, the
     indicator is lit.
   
   Processor Error LED    If the processor on the Advanced Remote
     Management Controller has failed, the
     indicator is lit.
   
   Ethernet Activity LED    If the Ethernet controller on the Advanced
     Remote Management Controller is
     transmitting data or receiving data, the
     indicator is lit.
   
   Ethernet Link LED    If an active link to the Ethernet controller on
     the Advanced Remote Management
     Controller is present, the indicator is lit.


Back to  Jump to TOP-of-PAGE