Array Problems
Many problems within an array are not seen by the users of the
server. The RAID-1 functions provide a continuing service to the
users even when a member of an array has failed. However, unless
the failure is corrected, a second failure within that array
could cause the whole array to become unavailable.
Therefore, it is very important that you check the error log for the adapter
regularly. You could do this by making such a check part of the start-up
procedure for your operating system. If an array is attached to a cluster
of servers, all errors in the array are logged to both servers.
Errors that occur during configuration might not be logged to both servers.
To check the error log:
The current list of errors appears in a new window:
If one of the following SRNs appears, you can correct the
problem by exchanging a disk drive for a new one:
Any SRN whose first character is '1'
60210
D0100
D0300
The following section describes what you need to do with the
array configuration utility while changing a disk drive.