Hot-Swap Power Supply Installation


Hot-Swap Power Supply Installation

The server comes with one power supply. You can add a second power supply to provide redundant power. After you install a power supply, check the power-supply status indicators to verify that the power supply is operating properly. See 'Power Supplies' for details.

 
Never remove the cover on a power supply or any part (power backplane and AC box) that has the following label attached.

 
Hazardous voltage, current, and energy levels are present inside the power supplies, power backplane, and AC box. There are no serviceable parts inside the power supplies, power backplane, or AC box.


Refer to the following illustration while performing the steps in this procedure.

Note: You do not need to turn off the power to the server to install hot-swap power supplies.


To add a power supply:

 
Never remove the cover on a power supply or any part (power backplane and AC box) that has the following label attached.

 
Hazardous voltage, current, and energy levels are present inside the power supplies, power backplane, and AC box. There are no serviceable parts inside the power supplies, power backplane, or AC box.

Note: It is not necessary to turn the Power switch on the power supply off when you are installing a power supply.

  1.  Remove the filler panel -3-:

    1.  Remove the four screws -2- from the filler panel.
    2.  Remove the filler panel -3- from the  power-supply bay and save it and the four  screws you removed for future use.

      Note:  During normal operation, each power-supply  bay should have either a power supply or  filler panel installed for proper cooling.

  2.  Place the handle -5- on the power supply in the open  position, and slide the power supply into the chassis.
  3.  Gently close the handle -5- on the power supply to  seat the power supply in the bay.
  4.  Plug the power cord for the added power supply into  power cord connector -1-.

     
     When the power-cord strain-relief bracket option  is installed on the power cord, the server must be  plugged to a power source that is easily  accessible.

  5.  Install a power-cord strain-relief bracket -10-, if  desired.
  6.  Plug the power cord into a properly grounded  electrical outlet.
  7.  Make sure the Power switch -6- on the power supply  is in the On position.
  8.  Verify that the DC Power light -8- and AC Power light  -7- on the power supply are lit, indicating that the  power supply is operating correctly.