Enabled Alerts Dialout Group
Use the selections available in the Enabled Alerts Dialout group to
specify which Advanced Systems Management Adapter events will
result in all currently configured Dialout Entries being contacted by
the Advanced Systems Management Adapter. Any selected items
will, if detected by the Advanced Systems Management Adapter,
result in an alert describing the event being forwarded, using the
method selected in the Type field, to the recipient specified by the
Dialout Entry. The Enable Alerts Dialout group is divided into
Critical, Non-Critical, and System groups.
Please see the LEGAL - Trademark notice.
The Critical Enabled Alerts Dialout group contains the following items.
Item / Numeric Code
Description (if checked)
Temperature 00
The Advanced Systems Management Adapter will dial
out if any monitored temperatures exceed their
threshold values and will then automatically initiate a
system shutdown.
Voltage 01
The Advanced Systems Management Adapter will dial
out if the voltages of any monitored power sources fall
outside their specified operational ranges.
Tamper 02
The system management subsystem will add an entry
in the Event Log if six consecutive remote login attempts fail.
Multiple fan 03
The Advanced Systems Management Adapter will dial
failure
out if two (or more) of the system's cooling fans fail
and will automatically initiate a system shutdown.
Note: This function is available only on some IBM
systems. For a list of systems that support
this feature, see 'Supported Advanced Functions'.
Power failure 04
The Advanced Systems Management Adapter will dial
out if the system's power supply fails.
Note: This function is available only on some IBM
systems. For a list of systems that support
this feature, see 'Supported Advanced Functions'.
Hard disk drive 05
The Advanced Systems Management Adapter will dial
out if one or more of the hard disk drives in the
system fail.
Note: This function is available only on some IBM
systems. For a list of systems that support
this feature, see 'Supported Advanced Functions'.
Voltage regulator 06
The system management subsystem will dial out and then
module failure
automatically initiate a subsystem shutdown if the voltage
regulator module (VRM) fails.
Note: This function is available only on some IBM systems.
The Non-critical Enabled Alerts Dialout group contains the following items.
Item / Numeric Code
Description (if checked)
Temperature 12
The Advanced Systems Management Adapter will dial
out if any monitored temperatures exceed their
threshold values. However, unlike the Critical
Temperature event, this Alerts Dialout will not initiate a
system shutdown automatically.
Note: This function is available only on some IBM
systems. For a list of systems that support
this feature, see 'Supported Advanced Functions'.
Single fan 11
The Advanced Systems Management Adapter will dial
failure
out if one of the system's cooling fans fail.
Note: This function is available only on some IBM
systems. For a list of systems that support
this feature, see 'Supported Advanced Functions'.
Voltage 13
The Advanced Systems Management Adapter will dial
out if any of the monitored voltages exceed their
threshold values.
The System Enabled Alerts Dialout group contains the following items.
Item / Numeric Code
Description (if checked)
POST timeout 20
The Advanced Systems Management Adapter will dial
out if the POST timeout value (specified in the
Service Processor Configuration Settings window) is
exceeded.
Loader timeout 26
The Advanced Systems Management Adapter will dial
out if the Loader timeout value (specified in the
Service Processor Configuration Settings window) is
exceeded.
O/S timeout 21
The Advanced Systems Management Adapter will dial
out if the O/S timeout value (specified in the Service
Processor Configuration Settings window) is exceeded.
Power off 23
The Advanced Systems Management Adapter will dial
out if the system is powered off.
Power on 24
The Advanced Systems Management Adapter will dial
out if the system is powered on.
Application 22
The Advanced Systems Management Adapter will dial
out if it receives a Netfinity alert (Netfinity can forward
alerts directly to the Advanced Systems Management
Adapter using the Alert Manager Forward Alert to
Service Processor action)
PFA 27
The Advanced Systems Management Adapter will dial
out if it receives a Predictive Failure Analysis (PFA) alert
from the system.
Back to
Feel free - send a for any BUG on this page found - Thank you.