Processor Card - Jumper (Netfinity 7000 - 8651)


Processor Card - Jumper

SCAN Jumpers A-SCAN J6B1 / B-SCAN J6D1

NOTE: The default settings for the scan jumpers is skip.
These settings do not affect the normal operation and there is no need to change them.

Jumper Loc Pin 1-2 Pin 2-3
SCAN-J6B1 A INCLUDE SKIP
SCAN-J6D1 B INCLUDE SKIP


Fan Sink Connectors C-J8A1 & J8A2 / D-J8C1 & J8C2. / E-J9B1

Connector Loc Pin 1 Pin 2 Pin 3
J8A1 & J8A2 C Ground Fan Fail +5V
J8C1 & J8C2 D Ground Fan Fail +5V
J9B1 E MBFANFAIL PRc1_PRC2 FailK2


Active/Passive Jumper F-Passive/Active J4B1

NOTE: The default setting for the active/passive jumper is passive and should not be changed.

Jumper Loc Pin 1-2 Pin 2-3
Passive/Active
J4B1
F Passive Active


Processor Speed Jumper G-J4D1

 

Processor Speed SEL0 SEL1 SEL2 Park0 Park1 Park2
200/66 MHz Jumper - Jumper Jumper - -


L2 Cache Jumper H-J1C1

NOTE: 512 KB jumper setting = 1 and 2, 3 and 4
1 MB jumper setting = 5 and 6, 7 and 8

 

Fan Fail Harness Connectors J-J1A1

Connector Loc Pin 1 Pin 2 Pin 3
J1A1 J - PRc1_PRC2 FailK1