Specifications (Netfinity 7000 - 8651)


Specifications

Size (Tower Model)

 ° Depth:  718 mm (28.3 in.)
 ° Height: 555 mm (21.9 in.)
 ° Width:  483 mm (lg.l in.)
 ° Front clearance:305 mm (12.0 in.)
 ° Rear clearance:127 mm (5.0 in.)
 ° Side clearance:76 mm (3.0 in.)
 Size (Rack          Model)
 ° Depth:  673 mm (26.5 in.)
 ° Height: 484 mm (19.1 in.) (approximately 11 EIA Units)
 ° Width:  437 mm (17.2 in.) (482 mm with mounting flanges)
 Weight
 ° Unpacked, minimum configurstion:
   54.5     kg (120 lb.)
 ° Unpacked, maximum configuration:
   72.6     kg (160 lb.)
 Electrical Input
 ° Sine-wave input (50 to 60 Hz) is required
 ° Input voltage
   -  Low range
   -  Minimum: 90 V ac
   -  Maximum:137 V ac
   -  High range
   -  Minimum:180 V ac
   -  Maximum:265 v ac
   -  Input kilovolt-amperes (KVA) approximately
   -  Minimum configuration as shipped:0.2 KVA
   -  Maximum configuration:0.78 KVA
 Environment
 ° Air temperature
   -  System on:0° to 35° C    (0° to 95° F)
      Altitude:0 to 914 m (3000 ft.)    C
   -  System on:0° to 32° C    (0° to 89.6° F)
      Altitude:914 m (3000 ft.) to 2133 m (7000 ft.)
   -  System off:10° to 43° C  (50° to 110° F)
      Maximum altitude:2133 m (7000 ft.)
 ° Humidity
   -  System on:
      8% to 80%, maximum wetbulb
      23° C (73.4° F)
   -  System off:
      8% to 80%, maximum wetbulb 27° C (80.6° F)
 ° Altitude:0 to 2133 m (0 to 7000 ft.)
 Electrostatic Discharge
 ° Tested to 20 KV
 Immunity
 ° Verified to comply with EN 50082-2
 Sound
 ° Sound Power, idling:
   - 6.2 bel for open bay system (no hard drives installed)
   - 6.3 bel for typical system configuration (1 bay tilled with hard drives)
 ° Sound Power, operating:
   - 6.2 bel for open bay system (no hard drives installed)
   - 6.4 bel for typical system configuration (1 bay filled with hard drives)
   Sound Pressure, idling:
   - 46 dBA for open bay system (no hard drives installed)
   - 46 dBA for typical system configuration (1 bay tilled with hard drives)
   Sound Pressure, operating:
   - 46 dBA for open bay system (no hard drives installed)
   - 47 dBA for typical system configuration (1 bay filled with hard drives)


These levels are measured in controlled acoustical environments according to ISO 7779 and are reported in accordance with ISO 9296. The declared sound power levels indicate an upper limit, below which a large portion of machines operate. Sound pressure levels in your location might exceed the average 1-meter values stated because of room reflections and other nearby noise.

 Heat Output
 ° Approximate heat output in
   British thermal units (BTU) per hour:
   -  Minimum configuration:1023.9 BTU
   -  Maximum configuration:2764.6 BTU
 Safety Standards
 ° UL 1950
 ° CSA C22.2 No. 950-M93
 ° EN 60950 and countries deviations
 ° IEC 950
 ° NOM-019


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.