Novell NetWare Server ODI Driver Messages



Novell NetWare Server ODI Driver Messages
This section contains the error messages for the Novell NetWare server ODI driver. The explanation and recommended action are included with each message.


PCNTNW-NW-026 The MSM is unable to parse a required custom keyword.
Explanation:
The user entered an incorrect parameter keyword.
Action: Enter the keyword correctly. Then, reload the driver.


PCNTNW-NW-054 The board did not respond to the initialization command.
Explanation:
The board did not respond when the driver tried to initialize it.
Action Perform the following steps

  1.  Verify that the Ethernet jumper on the system board is set  to the default, enabled position.
  2.  Go to 'General Checkout/Diagnostics QAPlus/PRO' to run the diagnostic utility.


PCNTNW-NW-58 The board did not respond to the initialization command.
Explanation:
The IRQ setting might be incorrect with the hardware setting, or the EEPROM might be corrupted.
Action: Perform the following steps

  1.  Verify that  the IRQ settings in the NET.CFG file  match the configuration settings in the Configuration/Setup utility programs.  See 'PCI Bus Control' for information on setting the interrupt  requests.
  2.  Verify that the EEPROM on the system board is programmed correctly.


PCNTNW-NW-66 The cable might be disconnected from the board.
Explanation:
The cable might be disconnected from the server's Ethernet port.
Action Verify that a cable is connected to the AUI port or the 10BASE-T port.


PCNTNW-NW-071 The matching virtual adapter could not be found.
Explanation:
You tried to load another instance of the driver with a different I/O address. This new board could not be found.
Action: If you installed an IBM Ethernet adapter, make sure the adapter is seated properly. Also, check the I/O settings of the board with the settings supplied to the drive.


PCNTNW-NW-072 A resource tag is unavailable.
Explanation.:
The driver tried to allocate some resources that were not available.
ActionAdd or free some memory in the server. Then, restart the server.


PCNTNW-NW-073 Unable to allocate memory.
Explanation:
The driver failed to allocate the memory needed for normal operation.
Action Add more memory, or free some memory resources in the server. Then, restart the server.


PCNTNW-NW-074 The hardware interrupt cannot be set.
Explanation:
An attempt was made to initialize a given hardware interrupt. The attempt was not successful.
Action Perform the following steps

  1.  Verify that the Ethernet jumper on the system board is set  to the default, enabled position.
  2.  Make sure that the interrupt  request numbers are set correctly, and that no other devices are  using the interrupt. See 'PCI Bus Control' for more information.


PCNTNW-NW-075 The MLID (Multiple Link Interface Driver) cannot be registered with the LSL.
Explanation:
An error occurred while the driver was trying to register with Link Support Layer.
Action Check the version of Netware Operating System. Make sure that this driver is correct for the version of Netware that you are using. Restart the server.


PCNTNW-NW-076 The polling procedure cannot be added.
Explanation:
An error occurred while the driver was adding a polling procedure to the Netware Operating System polling routines.
Action Check the version of Netware Operating System. Make sure that this driver is correct for the version of Netware that you are using. Restart the server.


PCNTNW-NW-077 The event notification cannot be registered.
Explanation:
The driver failed to register its event notification routines with the Netware Operating System.
Action Check the version of Netware Operating System. Make sure that this driver is correct for the version of Netware that you are using. Restart the server.


PCNTNW-NW-078 The firmware file cannot be read.
Explanation:
The driver to read a firmware file. The read process failed.
Action Make sure that the support files that accompany the driver are present. Restart the server.


PCNTNW-NW-079 The MLID (Multiple Link Interface Driver) did not initialize MSMTx Free Count.
Explanation:
The MSMTx Free Count is not initialized properly.
Action Restart the server. If the error recurs, replace the system board.


PCNTNW-NW-084 Unable to allocate memory below the 16 megabyte boundary.
Explanation:
A request was made to allocate memory below 16 megabytes. The request did not complete successfully.
Action Free some memory below 16 megabytes, or add more memory below the 16 megabyte boundary.


PCNTNW-NW-086 The driver parameter block is too small.
Explanation:
The driver parameter block is too small.
Action Restart the server. If the error recurs, replace the system board.


PCNTNW-NW-087 The media parameter block is too small.
Explanation:
The driver media parameter block is too small.
Action Restart the server. If the error recurs, replace the system board.


PCNTNW-NW-091 The hardware configuration conflicts.
Explanation:
You tried to load a new frame type for the existing adapter. The hardware assumptions made in doing so are incorrect.
Action Make sure that the hardware configuration matches the software settings. See 'PCI Bus Control' for information on viewing and changing interrupt requests.


PCNTNW-NW-092 Cannot schedule AES without an HSM routine.
Explanation:
The Netware Operating System needs a Hardware Support Module routine before it schedules an AES event.
Action Restart the server. If the error is still present, replace the system board.


PCNTNW-NW-093 Cannot schedule interrupt time call back without an HSM routine.
Explanation:
The driver needs a Hardware Support Module routine before it can schedule an interrupt time call back.
Action Restart the server. If the error recurs, replace the system board.


PCNTNW-NW-094 Cannot set hardware interrupt without an HSM routine.
Explanation:
The driver needs a hardware interrupt call back routine routine before it sets the interrupt.
Action Restart the server. If the error recurs, replace the system board.


PCNTNW-NW-095 Cannot add polling without an HSM routine.
Explanation:
The driver needs an HSM polling routine before it can start the polling process.
Action Restart the server. If the error recurs, replace the system board.


PCNTNW-NW-126 The group bit in the node address override was cleared.
Explanation:
The IEEE address has a group bit indicating that an address belongs to a group of stations. This bit is used only as a destination address it cannot be used as a source address. You tried to enter a source address with this bit set. The driver cleared the group bit of the source address.
Action: None.


PCNTNW-NW-127 The local bit in the node address override was set.
Explanation:
The local bit in the IEEE address format indicates that the addresses are being managed locally. If you use the node address override capabilities of this driver to enter a new address, the local bit should be set. You entered an address without the local bit set. The driver has set the local bit.
Action: None.


PCNTNW-NW-164 The device was not found.
Explanation:
The driver cannot find an Ethernet controller in the server.
Action: Perform the following steps

  1.  Verify that the Ethernet enable jumper is set to the default  (enable) position.
  2.  Go to 'General Checkout/Diagnostics QAPlus/PRO' to run the diagnostic utility.


PCNTNW-NW-164 Device not found at IOADDRESS.
Explanation:
The Ethernet controller cannot be found at the IO address specified in the NET.CFG file.
Action: Verify that the IO Address in the NET.CFG file matches with the board. Otherwise, remove the PORT keyword from the NET.CFG file.


PCNTNW-NW-167 PCI scan specified, device not found.
Explanation:
The driver cannot locate the Ethernet controller on the PCI bus.
Action: Perform the following steps

  1.  Verify that the Ethernet jumper on the system board is set to  the default, enable position.
  2.  Edit the NET.CFG file to change the BUSTYPE keyword to  PCI1.
  3.  If the problem persists, go to General Checkout/Diagnostics QAPlus/PRO to run the  diagnostic utility.


PCNTNW-NW-180 The DMA parameter is not necessary for PCI device.
Explanation:
The Ethernet controller does not require a DMA setting.
Action: Delete the DMA parameter from the NET.CFG file.