How to Run the Diagnostics



How to Run the Diagnostics

Use either the TrackPoint III or the cursor move keys to interact with the tests. The Enter key works the same as selecting the OK icon to reply OK.
  1.  Press and hold the F1 key, then power-on the computer.  Hold the F1 key down until Easy-setup screen appears.
  2.  Select Test and press Enter.
  3.  Select a device and press Enter to run the test.
     To test the Infrared Port, click the "SystemBoard" icon.
  4.  The test progress screen appears.
  5.  OK appears when the test ends without any errors.
  6.  Start the Advanced Diagnostic test by pressing Ctrl+A on the basic diagnostic menu screen.
  7.  Select Tool to install the tools.
  8.  Select a device, press the space key, and  install the tool. Multiple devices can be selected by repeating  this step.

    A OK mark appears for the selected device.

  9.  Select OK and press Enter  if the selection is OK.
  10.  Select a device and press Enter to start the tests.
  11.  Select Test All to test all devices.
  12.  Select Loop Test to loop tests.

    A loop option menu appears in which a device loop or all loop can be  selected. Select a device and press the space key to select  a device. Repeat this step to select multiple devices.  Press Enter to start the diagnostic loop. If no device is selected,  all device tests are looped.

  13.  To exit the loop,  keep pressing Ctrl+Pause until the test exits.  A beep sounds to notify  that the exit interrupt is sensed  by the test program.


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.