FRU Codes



FRU Codes

If an error is detected by the diagnostics tests, a four-digit  FRU code is displayed, along with an error code. The FRU code indicates two suspected FRUs. Replace the FRU that is indicated by the two leftmost digits  first, and then replace the FRU indicated by the two rightmost digits . No FRU is assigned to code 00. If only one FRU is suspected, the other FRU code is filled with zeros. See the referenced page before replacing the FRU.
FRU Code    FRU/Action
   10 1. Diskette Drive
  2. Bottom System Board
  3. Top System Board
   12    Top System Board
   14    Bottom System Board
   20    Memory
     (See 'Memory Checkout')
   32    External Keyboard
   33    External Mouse
   40    LCD Assembly
   (See 'Disassembling the LCD Assembly')  
   45    External CRT
   50 1. Reseat the Diskette Drive (FDD-1).
  2. Diskette Drive (FDD-1)
   51 1. Reseat the Diskette Drive (FDD-2).
  2. Diskette Drive (FDD-2)
   55 1. Insert a correctly
      formatted 2.0MB diskette
      into the Diskette Drive.
   60 1. Reseat the Hard Disk Drive (HDD-1).
  2. Hard Disk Drive (HDD-1)
   61 1. Reseat the Hard Disk Drive (HDD-2)
      on the docking station.
  2. Hard Disk Drive (HDD-2)
   70    External PCMCIA
   81    Internal Modem Card
   91    If MultiPort II is installed:
      1. Reseat MultiPort II.
      2. MultiPort II.
     If Dock II is installed:
      1. Reseat Dock II.
      2. Dock II


NOTE: The device ID and error codes are used to indicate in detail the portion of the FRU that caused the error. If replacing a FRU does not correct a problem, see the device ID or error code from the previous failure. If they have changed, the new FRU might be defective or incorrectly installed.

If the problem remains after replacement of the FRUs, go to 'Undetermined Problems'


Back to  Jump to TOP-of-PAGE

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.