**************> QUESTION level 1 --> level 2 SPECIALIST <**************         
We made some application using NV/6000 V2.1 APIs.                               
Our application calls OVwAlertMsg() to send message to nvevents.                
                                                                                
Our application abend calling OVwAlertMsg(), and error code was 1, it           
means "OVw_APP_NOT_FOUND". Programmers Reference says "There is no              
ovw application running that is dispatching alert messages"                     
                                                                                
But the time the trouble was occured, trapd and nvevents were running.          
We want to know what's the "ovw application running that is dis-                
patching alert messages", and why these error was occured.                      
                                                                                
Thanks and regards.                                                             
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                 
==== ASGN: NHL      AT WTSCPOK  ======================== DATE:951009           
TIME:0919                                                                       
Received by Raleigh ITSC and assigned to SHOGREN.                               
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== RESP: NHL      AT WTSCPOK  ======================== DATE:951009           
TIME:0946                                                                       
                                                                                
The only specialist we have who can answer this questions is out                
of the country at the present time.  He will be back on October 13th.           
Therefore we are closing this questions and ask that you reopen it              
again at the end of this week.                                                  
                                                                                
We are sorry for this inconvenience and thank you for your patience.            
************** ANSWER   level 2 -- level 1 SPECIALIST **************        
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== ASGN: WACKEROW AT WTSCPOK  ======================== DATE:951013           
TIME:1636                                                                       
The question has been re-assigned to WACKEROW.                                  
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== ASGN: WACKEROW AT WTSCPOK  ======================== DATE:951013           
TIME:1636                                                                       
The question has been re-assigned to SHOGREN.                                   
************** QUESTION level 1 -- level 2 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN JAPAN                                
                                                                                
CAN I ASK THIS QUESTION AGAIN ?                                                 
                                                                                
I HAD WRITTEN SAMPLE PROGRAM THAT CALL OVWALERTMSG() AND HANDLE ITS            
ERROR CODE.                                                                     
I TRIED TO EXEC THIS PROGRAM WITH STOPPING NVEVENTS, TRAPD, PMD AND             
OVESMD. BUT OVWALERTMSG() HAD NEVER RETURNED ERROR CODE 1.                      
                                                                                
PROGRAMMERS REFERENCE SAYS "WHEN THERE IS NO APPLICATION RUNNING THAT           
IS DISPATCHIG ALERT MESSAGES". WHAT ARE THE "APPLICATION" SPECIFICALLY          
                                                                                
                                                                                
THANKS AND REGARDS.                                                             
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== RESP: NHL      AT WTSCPOK  ======================== DATE:960215           
TIME:0806                                                                       
                                                                                
We have received your question and assigned it to a specialist.  We            
will respond as soon as possible.                                               
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== ASGN: NHL      AT WTSCPOK  ======================== DATE:960215           
TIME:0815                                                                       
The question has been re-assigned to SHOGREN.                                   
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== RESP: SHOGREN  AT WTSCPOK  ======================== DATE:960215           
TIME:0925                                                                       
Was an EUI running?                                                             
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== RESP: SHOGREN  AT WTSCPOK  ======================== DATE:960215           
TIME:1307                                                                      
I checked with Rob Macgregor and he confirms that, in our opinion,              
you did not have an EUI (ovw) running.                                          
************** QUESTION level 1 -- level 2 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN JAPAN                                
Sorry for my insufficient explanation, but I have an ovw running.               
                                                                                
I got this error when ovw starting and system (ovw) is very busy.               
I want to know what are the conditions to success OVwAlertMsg ( in              
other                                                                           
words, to not return error from OVwAlertMsg ).                                  
                                                                                
If ths OVwAlertMsg returns error, our application is terminated.                
I have registered the application to *.reg and enabled to restart from          
menu of NV. But the application terminated again when calling                   
OVwAlertMsg. In this case, ovw is not busy.                                    
                                                                                
If you like, let me know about mechanism of message dispatching.                
                                                                                
Thanks in advance.                                                              
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== RESP: NHL      AT WTSCPOK  ======================== DATE:960219           
TIME:0838                                                                       
                                                                                
We have received your question and assigned it to a specialist.  We             
will respond as soon as possible.                                               
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== ASGN: NHL      AT WTSCPOK  ======================== DATE:960219           
TIME:0851                                                                      
The question has been re-assigned to SHOGREN.                                   
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== RESP: SHOGREN  AT WTSCPOK  ======================== DATE:960219           
TIME:0857                                                                       
I will check with development.  I have seen situations where it ended           
up necessary to take the EUI down/up to recover from error situations           
caused by (for example) a time-out to a paricular call.                         
                                                                                
I will let you know if there are some hints.                                    
                                                                                
It could be you are headed down a product-defect (PMR) path.  We see.           
************** ANSWER   level 2 -- level 1 SPECIALIST **************         
==== THIS TEXT HAS BEEN ENTERED BY IBM IN USA                                  
==== RESP: SHOGREN  AT WTSCPOK  ======================== DATE:960220          
TIME:1234                                                                       
                                                                                
From/to development: (I will close this and assume that you will                
re-open                                                                         
it if you have more info.  Or, if you want, send the sample application         
to me: SHOGREN at WTSCPOK and let me see if I can reproduce your                
situation????? (We are on NetView for AIX V4, but that should not               
matter)                                                                         
                                                                                
                                                                                
 Dave,                                                                          
                                                                                
 I looked at the code and it seems as though you will get this error            
 message if there is no application currently registered to receive             
 ovw alerts (via the OVwAddAlertCallback() function).  I would                 
 have the customer check to see if they have any such applications              
 (noting that the Programmer's Reference says that a program that               
 registers for the events can not also generate them).                          
                                                                                
                                                                                
 From Dave:                                                                     
                                                                                
 I assumed, based upon their question, that they had applications               
 running which would satisfy their generated event; or, if they had             
 an EUI running that ovevent would satisfy it -- but, perhaps they get          
 the error when things are not started yet.  We see.                            
                                                                                
                                                                                
                                                                                
                                                                               


WWQA: ITEM: RS4000016652 ITEM: RS4000016652
Dated: 10/1995 Category: AIX6000
This HTML file was generated 99/06/24~12:43:06
Comments or suggestions? Contact us