In looking at the PSF/AIX Direct documentation, all the examples                
are for token-ring. I need examples for a 3172 ethernet connection.             
Are the examples in the PSF/2 Network Configuration Guide accurate              
or do they need modification? For example, it doesn't look like                 
PSF/AIX requires IDBLK and IDNUM. Thanks for the help.                          
A:                                                                              
The Token-Ring 3172 section of the PSF Direct Network Configuration             
Guide for PSF/AIX (S544-5287--make sure to get at least -01) is very           
similar to what you'll need for an Ethernet 3172 configuration. Between         
that and the Ethernet 3172 section in the PSF/2 Network Configuration           
Guide (S544-3511), you should have all the information you need.                
                                                                                
When it comes to SNA Server/6000, you can use the information in                
the PSF Direct Network Configuration Guide, local 3172 Token-Ring               
configuration (beginning on page 59), with the understanding that you'll        
need to create an Ethernet SNA DLC Profile and an Ethernet Link Station         
Profile rather than Token-Ring DLC and LS profiles.                             
                                                                                
Regarding IDNUM/IDBLK, in AIX you have the option to use CPNAME                 
instead of IDNUM/IDBLK for the SNA Control Point profile and in VTAM            
if so desired. If your customer wants to use IDBLK, the value would be          
071 instead of 05D (which is used for PSF/2 DPF or Direct).                     
                                                                               